Literature DB >> 16374275

Comparison of hemorrhage control agents applied to lethal extremity arterial hemorrhages in swine.

Eric M Acheson1, Bijan S Kheirabadi, Rodolfo Deguzman, Edward J Dick, John B Holcomb.   

Abstract

BACKGROUND: QuikClot powder (QC), chitosan dressing (CD), and fibrin sealant dressing (FSD) are new hemostatic products touted to be more effective in controlling severe extremity bleeding than the current standard gauze dressing. All have been utilized in the global war on terrorism. Our objective was to evaluate the hemostatic efficacy of these three products in a model of severe extremity arterial hemorrhage that could not be stopped by standard gauze treatment.
METHODS: A model of severe extremity arterial hemorrhage was developed in swine that was 100% fatal with standard gauze application and manual compression. The Army Field Bandage (AFB) was the standard gauze control. Anesthetized animals (n = 60, 15/group, 37.7 +/- 2.5 kg) were splenectomized and instrumented. A reproducible femoral artery injury was created using a 6 mm aortic punch, and free bleeding was allowed for 45 seconds. Each hemostatic agent was applied twice with three-minute compressions. All products were applied on actively bleeding wounds through a pool of blood. Fluid resuscitation was started with the first compression and titrated to a mean pressure of 65 mm Hg. Animals were observed for 180 minutes or until death. Endpoints were percent survival, survival time, blood loss, resuscitation volume, wound temperatures and tissue histology. Data are expressed as mean +/- SD and analyzed by Fisher's exact, logrank, and nonparametric ANOVA tests.
RESULTS: Baseline physiologic parameters were similar among groups. AFB did not produce hemostasis. QC also showed no hemostatic benefit, and QC treatment markedly increased maximum wound temperatures to an average of 70.8 +/- 4.2 degrees C (p < 0.001). CD stopped bleeding temporarily in only one animal. There were no survivors in the AFB, QC, or CD groups. CD numerically prolonged survival time (58.9 +/- 21.1 minute) compared with the control (38.4 +/- 24.7 minutes, p = 0.045) but the difference was not significant. FSD reduced bleeding (p < 0.05) and prevented exsanguination in 10/15 (2/3) animals, and resulted in a significantly longer average survival time (p < 0.0001).
CONCLUSION: FSD was superior to other currently utilized hemostatic products in controlling lethal arterial hemorrhage in this model of a fatal extremity wound. CD showed some hemostatic benefit. The exothermic reaction of QC was significant and resulted in gross and histologic tissue changes of unknown clinical significance. Controlled human studies with the promising products are required.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16374275     DOI: 10.1097/01.ta.0000187655.63698.9f

Source DB:  PubMed          Journal:  J Trauma        ISSN: 0022-5282


  13 in total

Review 1.  Topical and effective hemostatic medicines in the battlefield.

Authors:  Yin-Juan Zhang; Bo Gao; Xi-Wen Liu
Journal:  Int J Clin Exp Med       Date:  2015-01-15

Review 2.  Current use of live tissue training in trauma: a descriptive systematic review.

Authors:  Luis Teodoro da Luz; Bartolomeu Nascimento; Homer Tien; Michael J Kim; Avery B Nathens; Savvas Vlachos; Elon Glassberg
Journal:  Can J Surg       Date:  2015-06       Impact factor: 2.089

3.  Hemostatic gauze based on chitosan and hydroquinone: preparation, characterization and blood coagulation evaluation.

Authors:  Roberta Cassano; Maria Luisa Di Gioia; Silvia Mellace; Nevio Picci; Sonia Trombino
Journal:  J Mater Sci Mater Med       Date:  2017-11-07       Impact factor: 3.896

4.  Self-Propelled Dressings Containing Thrombin and Tranexamic Acid Improve Short-Term Survival in a Swine Model of Lethal Junctional Hemorrhage.

Authors:  James R Baylis; Alexander E St John; Xu Wang; Esther B Lim; Matthew L Statz; Diana Chien; Eric Simonson; Susan A Stern; Richard T Liggins; Nathan J White; Christian J Kastrup
Journal:  Shock       Date:  2016-09       Impact factor: 3.454

Review 5.  [Hemostyptics for treatment of junctional vascular injuries : Management of traumatic vascular injuries at the transition from trunk to extremities].

Authors:  D C Hinck; S Wipper; E S Debus
Journal:  Unfallchirurg       Date:  2018-07       Impact factor: 1.000

6.  A novel hemostatic sealant composed of gelatin, transglutaminase and thrombin effectively controls liver trauma-induced bleeding in dogs.

Authors:  Xia Xie; Jiang-ke Tian; Fa-qin Lv; Rong Wu; Wen-bo Tang; Yu-kun Luo; Ya-qin Huang; Jie Tang
Journal:  Acta Pharmacol Sin       Date:  2013-05-06       Impact factor: 6.150

Review 7.  Hemostatic strategies for traumatic and surgical bleeding.

Authors:  Adam M Behrens; Michael J Sikorski; Peter Kofinas
Journal:  J Biomed Mater Res A       Date:  2013-12-12       Impact factor: 4.396

8.  Celox-coated gauze for the treatment of civilian penetrating trauma: a randomized clinical trial.

Authors:  Hamid Reza Hatamabadi; Fatemeh Asayesh Zarchi; Hamid Kariman; Ali Arhami Dolatabadi; Ali Tabatabaey; Afshin Amini
Journal:  Trauma Mon       Date:  2015-01-20

9.  Comparison of hemostatic dressings for superficial wounds using a new spectrophotometric coagulation assay.

Authors:  Julian-Dario Rembe; Julia K Böhm; Carolin Fromm-Dornieden; Nadine Schäfer; Marc Maegele; Matthias Fröhlich; Ewa K Stuermer
Journal:  J Transl Med       Date:  2015-11-30       Impact factor: 5.531

10.  The iTClamp controls junctional bleeding in a lethal swine exsanguination model.

Authors:  Dennis Filips; Sarvesh Logsetty; Jonathan Tan; Ian Atkinson; Kelly Mottet
Journal:  Prehosp Emerg Care       Date:  2013-08-22       Impact factor: 3.077

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.