Literature DB >> 16371786

Oxygen transmissibility of piggyback systems with conventional soft and silicone hydrogel contact lenses.

Antonio López-Alemany1, José M González-Méijome, José B Almeida, Manuel A Parafita, Miguel F Refojo.   

Abstract

PURPOSE: To investigate the apparent oxygen transmissibility of various piggyback systems using conventional and silicone hydrogel soft contact lenses of different water content and permeability, rigid poly(methyl methacrylate), and rigid gas-permeable lenses of medium, high, and ultrahigh oxygen permeability. The aim of the study was to establish which material (rigid or hydrogel) is more representative of the resulting oxygen performance of piggyback systems.
METHODS: The apparent oxygen transmissibility of 66 piggyback systems was measured with an electrochemical method. Eighteen of these combinations involved the use of silicone hydrogel contact lenses currently available. One hyperpermeable rigid gas-permeable contact lens (tisilfocon A) was also included in the study.
RESULTS: Measured apparent transmissibility correlates with rigid lens permeability (r = 0.403; SE = +/-3.03 barrer/cm; P < 0.001) and hydrogel lens permeability (r = 0.334; SE = +/-3.2 barrer/cm; P < 0.001). As expected, a linear model comprising permeability values from both rigid and soft materials gave a more precise estimation of the piggyback transmissibility (r = 0.736; SE = +/-2.02 barrer/cm; P < 0.001). The highest values of apparent oxygen transmissibility were found for the combination of tisilfocon A rigid material with any of the 3 silicone hydrogel lenses. Tisilfocon A material significantly improved the transmissibility of all piggyback systems even when conventional hydrogels are involved.
CONCLUSION: The combination of hypertransmissible rigid gas permeable lenses with silicone hydrogel soft materials should result in normal corneal function under daily wear conditions. When fitting piggyback systems, clinicians must be aware of material selection to optimize oxygen performance. This is of particular importance in already compromised corneas.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16371786     DOI: 10.1097/01.ico.0000178276.90892.ac

Source DB:  PubMed          Journal:  Cornea        ISSN: 0277-3740            Impact factor:   2.651


  4 in total

1.  High Dk piggyback contact lens system for contact lens-intolerant keratoconus patients.

Authors:  Tomris Sengor; Sevda Aydin Kurna; Suat Aki; Yelda Ozkurt
Journal:  Clin Ophthalmol       Date:  2011-03-03

Review 2.  Nonsurgical Procedures for Keratoconus Management.

Authors:  L Rico-Del-Viejo; M Garcia-Montero; J L Hernández-Verdejo; S García-Lázaro; F J Gómez-Sanz; A Lorente-Velázquez
Journal:  J Ophthalmol       Date:  2017-12-21       Impact factor: 1.909

3.  Contact Lenses for Keratoconus- Current Practice.

Authors:  Marilita M Moschos; Eirini Nitoda; Panagiotis Georgoudis; Miltos Balidis; Eleftherios Karageorgiadis; Nikos Kozeis
Journal:  Open Ophthalmol J       Date:  2017-07-31

4.  Update on Contact Lens Treatment of Keratoconus

Authors:  Tomris Şengör; Sevda Aydın Kurna
Journal:  Turk J Ophthalmol       Date:  2020-08-26
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.