Literature DB >> 16371523

Use of the peripheral cutting balloon to treat hemodialysis-related stenoses.

Thomas M Vesely1, Jeffrey B Siegel.   

Abstract

PURPOSE: To compare the effectiveness and safety of use of the peripheral cutting balloon (PCB) versus standard percutaneous transluminal angioplasty (PTA) for the treatment of hemodialysis-related stenoses.
MATERIALS AND METHODS: This prospective, randomized multicenter clinical trial included 340 patients with stenotic or thrombosed hemodialysis grafts who were randomized to receive treatment with the PCB or PTA for venous outflow stenosis. One hundred seventy-three patients underwent treatment with the PCB, 101 with stenotic grafts and 72 with thrombosed grafts. PTA was used to treat 167 patients, 94 patients with stenotic grafts and 73 with thrombosed grafts. The follow-up period extended for 6 months.
RESULTS: The procedural success rates were 80.8% and 75.4% for the PCB and PTA groups, respectively (P = .24). With use of the PCB, the primary patency rates of the target lesions were 84.3%, 65.8%, and 47.9% at 1 month, 3 months, and 6 months, respectively. With PTA, the primary patency rates of the target lesions were 77.7%, 63.4%, and 40.5% at 1 month, 3 months, and 6 months, respectively. The primary patency rates of the entire vascular access circuit were 82.6%, 61.0%, and 43.3% at 1 month, 3 months, and 6 months, respectively, with use of the PCB. For patients who were treated with PTA, the primary patency rates of the vascular access circuit were 75.9%, 61.0%, and 36.3% at 1 month, 3 months, and 6 months, respectively. When comparing the PCB and PTA, there was no difference in the 6-month primary patency rates in the target lesion (P = .373) or the entire vascular access circuit (P = .531). There were nine device-related complications in the PCB group (5.2%): five venous ruptures (2.9%), three venous dissections (1.7%), and one case of thrombosis (0.6%). There were no device-related complications in the PTA group.
CONCLUSION: This prospective, randomized trial comparing use of the PCB versus standard PTA for treatment of hemodialysis-related venous stenoses demonstrated that the PCB provides equivalent 6-month patency to PTA for stenotic and thrombosed grafts.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16371523     DOI: 10.1097/01.RVI.0000190928.19701.DD

Source DB:  PubMed          Journal:  J Vasc Interv Radiol        ISSN: 1051-0443            Impact factor:   3.464


  6 in total

1.  Dialysis: the stent graft for stenosis: let's appraise before we praise.

Authors:  Loay Salman; Arif Asif
Journal:  Nat Rev Nephrol       Date:  2010-09       Impact factor: 28.314

Review 2.  Novel therapies for hemodialysis vascular access dysfunction: myth or reality?

Authors:  Christi M Terry; Laura M Dember
Journal:  Clin J Am Soc Nephrol       Date:  2013-11-14       Impact factor: 8.237

Review 3.  Pre-emptive correction for haemodialysis arteriovenous access stenosis.

Authors:  Pietro Ravani; Robert R Quinn; Matthew J Oliver; Divya J Karsanji; Matthew T James; Jennifer M MacRae; Suetonia C Palmer; Giovanni F M Strippoli
Journal:  Cochrane Database Syst Rev       Date:  2016-01-07

4.  Efficacy of SMART Stent Placement for Salvage Angioplasty in Hemodialysis Patients with Recurrent Vascular Access Stenosis.

Authors:  Shingo Hatakeyama; Terumasa Toikawa; Akiko Okamoto; Hayato Yamamoto; Kengo Imanishi; Teppei Okamoto; Noriko Tokui; Yuichiro Suzuki; Naoki Sugiyama; Atsushi Imai; Yasuhiro Hashimoto; Shigemasa Kudo; Takahiro Yoneyama; Takuya Koie; Noritaka Kamimura; Hisao Saitoh; Tomihisa Funyu; Chikara Ohyama
Journal:  Int J Nephrol       Date:  2011-11-20

5.  Arteriovenous Access Failure, Stenosis, and Thrombosis.

Authors:  Jennifer M MacRae; Christine Dipchand; Matthew Oliver; Louise Moist; Charmaine Lok; Edward Clark; Swapnil Hiremath; Joanne Kappel; Mercedeh Kiaii; Rick Luscombe; Lisa M Miller
Journal:  Can J Kidney Health Dis       Date:  2016-09-27

6.  Clinical outcomes following the surgery of new autologous arteriovenous fistulas proximal to the failed ones in end-stage renal disease patients: a retrospective cohort study.

Authors:  Xianglei Kong; Lijun Tang; Liming Liang; Wei Cao; Lei Zhang; Wei Yong; Nannan Ding; Wenbin Li; Zunsong Wang; Dongmei Xu
Journal:  Ren Fail       Date:  2019-11       Impact factor: 2.606

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.