Literature DB >> 16371297

FemCap with removal strap: ease of removal, safety and acceptability.

Christine K Mauck1, Debra H Weiner, Mitchell D Creinin, David F Archer, Jill L Schwartz, Helen C Pymar, Susan A Ballagh, Deborah M Henry, Marianne M Callahan.   

Abstract

OBJECTIVES: FemCap is a silicone-rubber barrier contraceptive approved for marketing in the United States. To address reported problems with removal and dislodgment, the device's developer added a strap to the device and increased the height of the brim. This trial assessed whether the new design reduced removal difficulties and had any effects on dislodgment, genital pain/discomfort, safety, and acceptability.
METHODS: Women used the strapped device for 8 weeks with follow-up visits at 2 and 8 weeks. Outcome measures were obtained through diary cards, questionnaires, and naked eye examination. Data from these 120 women were compared with data from 419 women who used the unstrapped FemCap in a previous contraceptive effectiveness study.
RESULTS: The strapped device was not significantly easier for users to remove than the unstrapped device. Similar odds of dislodgment and cervical/vaginal irritation were seen with the two devices. Both female and male participants were significantly more likely to report pain/discomfort with use of the strapped device. Female users of the strapped device were significantly more likely to say they disliked their device. In six weeks, two pregnancies were observed, but pregnancy was not an endpoint in the study and no conclusions should be drawn regarding pregnancy rates.
CONCLUSIONS: The modifications to the FemCap did not significantly improve the ease of device removal and appears to have resulted in significantly more female and male partner pain/discomfort and decreased acceptability, compared with the unstrapped device.

Entities:  

Mesh:

Year:  2005        PMID: 16371297      PMCID: PMC2876188          DOI: 10.1016/j.contraception.2005.06.074

Source DB:  PubMed          Journal:  Contraception        ISSN: 0010-7824            Impact factor:   3.375


  2 in total

1.  A comparative study of the safety and efficacy of FemCap, a new vaginal barrier contraceptive, and the Ortho All-Flex diaphragm. The FemCap Investigators' Group.

Authors:  C Mauck; M Callahan; D H Weiner; R Dominik
Journal:  Contraception       Date:  1999-08       Impact factor: 3.375

2.  Design and analysis of randomized clinical trials requiring prolonged observation of each patient. II. analysis and examples.

Authors:  R Peto; M C Pike; P Armitage; N E Breslow; D R Cox; S V Howard; N Mantel; K McPherson; J Peto; P G Smith
Journal:  Br J Cancer       Date:  1977-01       Impact factor: 7.640

  2 in total