Numerical study of the impact of non-Newtonian blood behavior on flow over a two-dimensional backward facing step.

Hyo Won Choi1, Abdul I Barakat.   

Abstract

Endothelial cell (EC) responsiveness to shear stress is essential for vasoregulation and plays a role in atherogenesis. Although blood is a non-Newtonian fluid, EC flow studies in vitro are typically performed using Newtonian fluids. The goal of the present study was to determine the impact of non-Newtonian behavior on the flow field within a model flow chamber capable of producing flow disturbance and whose dimensions permit Reynolds and Womersley numbers comparable to those present in vivo. We performed two-dimensional computational fluid dynamic simulations of steady and pulsatile laminar flow of Newtonian and non-Newtonian fluids over a backward facing step. In the non-Newtonian simulations, the fluid was modeled as a shear-thinning Carreau fluid. Steady flow results demonstrate that for Re in the range 50-400, the flow recirculation zone downstream of the step is 22-63% larger for the Newtonian fluid than for the non-Newtonian fluid, while spatial gradients of shear stress are larger for the non-Newtonian fluid. In pulsatile flow, the temporal gradients of shear stress within the flow recirculation zone are significantly larger for the Newtonian fluid than for the non-Newtonian fluid. These findings raise the possibility that in regions of flow disturbance, EC mechanotransduction pathways stimulated by Newtonian and non-Newtonian fluids may be different.

Mesh:

Year:  2005        PMID: 16369086

Source DB:  PubMed          Journal:  Biorheology        ISSN: 0006-355X            Impact factor:   1.875


  7 in total

1.  Numerical modeling of the flow in intracranial aneurysms: prediction of regions prone to thrombus formation.

Authors:  V L Rayz; L Boussel; M T Lawton; G Acevedo-Bolton; L Ge; W L Young; R T Higashida; D Saloner
Journal:  Ann Biomed Eng       Date:  2008-09-12       Impact factor: 3.934

2.  Hemodynamically driven stent strut design.

Authors:  Juan M Jiménez; Peter F Davies
Journal:  Ann Biomed Eng       Date:  2009-05-27       Impact factor: 3.934

3.  A Computational Fluid Dynamics Study of the Extracorporeal Membrane Oxygenation-Failing Heart Circulation.

Authors:  Farhad Rikhtegar Nezami; Farhan Khodaee; Elazer R Edelman; Steven P Keller
Journal:  ASAIO J       Date:  2021-03-01       Impact factor: 3.826

4.  Non-Newtonian Endothelial Shear Stress Simulation: Does It Matter?

Authors:  Vikas Thondapu; Daisuke Shishikura; Jouke Dijkstra; Shuang J Zhu; Eve Revalor; Patrick W Serruys; William J van Gaal; Eric K W Poon; Andrew Ooi; Peter Barlis
Journal:  Front Cardiovasc Med       Date:  2022-04-14

5.  Effect of saline injection mixing on accuracy of conductance lumen sizing of peripheral vessels.

Authors:  Hyo Won Choi; Benjamin Jansen; David Birrer; Ghassan S Kassab
Journal:  PLoS One       Date:  2013-09-13       Impact factor: 3.240

6.  Computerized two-lead resting ECG analysis for the detection of coronary artery stenosis.

Authors:  Eberhard Grube; Andreas Bootsveld; Seyrani Yuecel; Joseph T Shen; Michael Imhoff
Journal:  Int J Med Sci       Date:  2007-10-16       Impact factor: 3.738

7.  Computational Fluid Dynamic Simulations of Maternal Circulation: Wall Shear Stress in the Human Placenta and Its Biological Implications.

Authors:  E Lecarpentier; M Bhatt; G I Bertin; B Deloison; L J Salomon; P Deloron; T Fournier; A I Barakat; V Tsatsaris
Journal:  PLoS One       Date:  2016-01-27       Impact factor: 3.240

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.