Literature DB >> 16368246

Electromyographic instantaneous amplitude and instantaneous mean power frequency patterns across a range of motion during a concentric isokinetic muscle action of the biceps brachii.

Travis W Beck1, Terry J Housh, Glen O Johnson, Joel T Cramer, Joseph P Weir, Jared W Coburn, Moh H Malek.   

Abstract

The purpose of this study was to examine the electromyographic (EMG) instantaneous amplitude (IA) and instantaneous mean power frequency (IMPF) patterns for the biceps brachii muscle across a range of motion during maximal and submaximal concentric isokinetic muscle actions of the forearm flexors. Ten adults (mean +/- SD age = 22.0 +/- 3.4 years) performed a maximal and a submaximal [20% peak torque (PT)] concentric isokinetic forearm flexion muscle action at a velocity of 30 degrees s(-1). The surface EMG signal was detected from the biceps brachii muscle with a bipolar electrode arrangement, and the EMG IA and IMPF versus time relationships were examined for each subject using first- and second-order polynomial regression models. The results indicated that there were no consistent patterns between subjects for EMG IA or IMPF with increases in torque across the range of motion. Some of the potential nonphysiological factors that could influence the amplitude and/or frequency contents of the surface EMG signal during a dynamic muscle action include movement of the muscle fibers and innervation zone beneath the skin surface, as well as changes in muscle fiber length and the thickness of the tissue layer between the muscle and the recording electrodes. These factors may affect the EMG IA and IMPF patterns differently for each subject, thereby increasing the difficulty of drawing any general conclusions regarding the motor control strategies that increase torque across a range of motion.

Entities:  

Mesh:

Year:  2005        PMID: 16368246     DOI: 10.1016/j.jelekin.2005.10.002

Source DB:  PubMed          Journal:  J Electromyogr Kinesiol        ISSN: 1050-6411            Impact factor:   2.368


  2 in total

1.  Simultaneous and Continuous Estimation of Shoulder and Elbow Kinematics from Surface EMG Signals.

Authors:  Qin Zhang; Runfeng Liu; Wenbin Chen; Caihua Xiong
Journal:  Front Neurosci       Date:  2017-05-30       Impact factor: 4.677

2.  Characterization of Textile-Insulated Capacitive Biosensors.

Authors:  Charn Loong Ng; Mamun Bin Ibne Reaz
Journal:  Sensors (Basel)       Date:  2017-03-12       Impact factor: 3.576

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.