Literature DB >> 16363620

Do short-time SPECT images of bone scintigraphy improve the diagnostic value in the evaluation of solitary lesions in the thoracic spine in patients with extraskeletal malignancies?

Kana Kobayashi1, Chio Okuyama, Takao Kubota, Takako Nakai, Yo Ushijima, Tsunehiko Nishimura.   

Abstract

OBJECTIVE: Single photon emission computed tomography (SPECT) images provide many details of the anatomical structure. Also about bone scintigraphy, there are many reports of the improvement of diagnosis by SPECT images. Although SPECT is useful, it requires much time. So to perform SPECT for all cases is difficult in the clinical situation. Recently, due to technical improvements in gamma cameras, we can get SPECT images in a short time. We examined diagnosis of solitary hot spots of thoracic spine in cancer patients using short-time SPECT. And we considered whether short-time SPECT contributes to the precise diagnosis of the lesion.
MATERIAL AND METHODS: We performed bone scintigraphy image acquisition and both planar and short-time SPECT of the chest. Short-time SPECT was acquired in 6 minutes. We selected 36 cases with malignancy, whose bone scintigraphy demonstrated a solitary accumulation hot spot in the thoracic spine. Three experienced radiologists in nuclear medicine and 4 beginners diagnosed the images. They interpreted planar, short-time SPECT and maximum intensity projection (MIP) view of the chest of each case. The observers' response data were analyzed with receiver operating characteristic (ROC) curve analysis.
RESULTS: Of the three types of images, the Az (the area under ROC curve) values of short-time SPECT were the highest in all the observers except for only one beginner. Compared with experienced observers, beginners scored lower Az values of short-time SPECT. MIP images were constructed using SPECT data, but the Az values of MIP images were not higher than those of planar images. As to diagnosis, beginners tended to interprete most of the accumulations as metastatic lesions.
CONCLUSION: Short-time SPECT can be helpful to some degree, but to provide greater benefit, the observers require considerable exercise and experience.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16363620     DOI: 10.1007/bf02985048

Source DB:  PubMed          Journal:  Ann Nucl Med        ISSN: 0914-7187            Impact factor:   2.668


  4 in total

1.  Clinical study of the application of SPECT, CT, and SPECT/CT for diagnosing rib diseases.

Authors:  Runqing Duan; Hongcheng Shi
Journal:  Jpn J Radiol       Date:  2015-01-29       Impact factor: 2.374

2.  Radionuclide bone SPECT/CT in the evaluation of knee pain: comparing two-phase bone scintigraphy, SPECT and SPECT/CT.

Authors:  Suat-Jin Lu; Fahim Ul Hassan; Sanjay Vijayanathan; Gopinath Gnanasegaran
Journal:  Br J Radiol       Date:  2018-09-11       Impact factor: 3.039

3.  The clinical rehabilitation of spine and spinal cord disorders: detection and evaluation using SPECT/CT.

Authors:  Max J Scheyerer; Clément M L Werner; Patrick Veit-Haibach
Journal:  Neural Regen Res       Date:  2014-04-15       Impact factor: 5.135

4.  Focal hot spot induced by a central subclavian line on bone scan.

Authors:  Masood Moslehi; Mohsen Cheki; Tohid Dehghani; Mansoureh Eftekhari
Journal:  Adv Biomed Res       Date:  2014-11-29
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.