Resolution of biparametric mixtures using bead injection spectroscopic flow-through renewable surface sensors.

M J Ruedas-Rama1, A Ruiz-Medina, A Molina-Díaz.   

Abstract

A new, sensitive and simple bead injection spectroscopy-flow injection analysis (BIS-FIA) sensor with spectrophotometric detection, using a commercially available flow-cell, is described to the determination of biparametric mixtures. As an analytical model, the metallic mixture Cu(II) and Zn(II) has been chosen. The flow-cell (Hellma 138-OS) is filled by injecting in the flow system 300 microl of a homogeneous bead suspension of an anion exchanger gel (Sephadex QAE A-25) previously loaded with the chromogenic reagent 2-carboxyl-2-hydroxy-5-sulfoformazylbenzene (Zincon). A sequential reaction of Cu(II) and Zn(II) with Zincon to form two complexes is performed on the bead sensing support and the absorbance is monitored at 627 nm, after two successive injections from the mixture solution. The sample containing these metal ions is injected into the first carrier (deionized water, pH 5.9), and Cu(II) selectively reacts with Zincon on the beads, developing the analytical signal. Then, 600 microl of 2 M HCl is injected to decompose the complex, and the carrier solution is changed. At pH 11 (second carrier) both Cu(II) and Zn(II) react with the chromogenic reagent, the absorbance now corresponding to both analytes. The eluent is again injected to descompose both complexes. After three analyses the sensing bead surface is not regenerated. Then, beads are automatically discarded from the flow cell by reversal of the flow, and instantaneously transported out of the system. So the procedure exploits the combination of the concepts of flow-through renewable sensors with bead injection spectroscopy. Using a sample volume of 1000 microl, the calibration graph for Cu(II) is linear over the range 0.05 to 1 microg ml(-1) and for Zn(II) from 0.1 to 1.8 microg ml(-1) in the presence of each other. RSDs (%) lower than 5% are obtained for both analytes. The sensor is satisfactorily applied to individual determination or mixture resolution in waters, pharmaceuticals, soils and human hair samples.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16363477     DOI: 10.2116/analsci.21.1079

Source DB:  PubMed          Journal:  Anal Sci        ISSN: 0910-6340            Impact factor:   2.081


  2 in total

Review 1.  State-of-the-art of (bio)chemical sensor developments in analytical Spanish groups.

Authors:  María Reyes Plata; Ana María Contento; Angel Ríos
Journal:  Sensors (Basel)       Date:  2010-03-24       Impact factor: 3.576

2.  Use of a Polymer Inclusion Membrane and a Chelating Resin for the Flow-Based Sequential Determination of Copper(II) and Zinc(II) in Natural Waters and Soil Leachates.

Authors:  Tânia C F Ribas; Charles F Croft; M Inês G S Almeida; Raquel B R Mesquita; Spas D Kolev; António O S S Rangel
Journal:  Molecules       Date:  2020-10-31       Impact factor: 4.411

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.