Cardiac dysrhythmias after transcatheter closure of ASD with Amplatzer device.

Alpay Celiker1, Süheyla Ozkutlu, Cemşit Karakurt, Tevfik Karagöz.   

Abstract

Transcatheter closure of atrial septal defect (ASD) has been used as an alternative to open heart surgery. Although transcatheter closure of ASD with the Amplatzer septal occluder is a safe and feasible method in pediatric patients, there is little published data on arrhythmia analysis following transcatheter device closure of secundum ASD. We evaluated cardiac dysrhythmias with 24-hour ambulatory electrocardiographic (ECG) monitoring after transcatheter closure of ASD with Amplatzer device. A total of 85 consecutive patients with ASD underwent transcatheter closure of secundum ASD with Amplatzer device between October 1998 and December 2003. The study involved 65 of these patients assessed by 24-hour ambulatory ECG monitoring. Seven patients were evaluated a second time by 24-hour monitorization. During the procedure, transient complete atrioventricular (AV) block was seen in two patients. One of them returned to normal sinus rhythm in catheterization lab and the other returned to normal sinus rhythm in two hours. Transient junctional rhythm was observed in another patient during the device placement. Twenty-four hour ambulatory ECG monitoring was performed on all patients after a mean four-month period (1-12 months). Holter recordings demonstrated rare supraventricular extrasystole in two patients, rare ventricular premature beats in two patients, and intermittent sinus arrest with sinus pause lasting <1.5 seconds in one patient, for a total of five patients (7.6%). In conclusion, dysrhythmias after transcatheter device closure of secundum ASD with Amplatzer device are rare and benign. We need further long-term follow-up to evaluate late dysrhythmias after the transcatheter device closure of secundum ASD.

Entities:  

Mesh:

Year:  2005        PMID: 16363340

Source DB:  PubMed          Journal:  Turk J Pediatr        ISSN: 0041-4301            Impact factor:   0.552


  3 in total

1.  Risk factors and prognosis of atrioventricular block after atrial septum defect closure using the Amplatzer device.

Authors:  Yibin Wang; Yimin Hua; Li Li; Xiaoqin Wang; Lina Qiao; Xiaoqing Shi; Jiping Hua; Yi Qu; Dezhi Mu
Journal:  Pediatr Cardiol       Date:  2013-10-30       Impact factor: 1.655

2.  Percutaneous Closure of Atrial Septal Defects with the MemoPart Atrial Septal Occluder: The Early-Term Results of a Multicenter Study.

Authors:  Ali Baykan; Meki Bilici; Nazmi Narin; Abdullah Erdem; Kazim Uzum; Alper Akin; Ozge Pamukcu; Hasan Balik; Mehmet Ture; Cagdas Vural; Alper Dogan
Journal:  Pediatr Cardiol       Date:  2021-08-16       Impact factor: 1.655

3.  Holter electrocardiography findings and P-wave dispersion in pediatric patients with transcatheter closure of atrial septal defects.

Authors:  Isa Ozyilmaz; Sinem Ozyilmaz; Hasan Tahsin Tola; Murat Saygi; Neslihan Kiplapinar; Cansaran Tanıdır; Yakup Ergul; Alper Guzeltas; Ender Odemis
Journal:  Ann Noninvasive Electrocardiol       Date:  2013-10-08       Impact factor: 1.468

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.