Literature DB >> 16362524

Hollow-fiber blood-dialysis membranes: superoxide generation, permeation, and dismutation measured by chemiluminescence.

Ken-ichiro Yamamoto1, Kazuyoshi Kobayashi, Kosuke Endo, Takehiro Miyasaka, Seiichi Mochizuki, Fukashi Kohori, Kiyotaka Sakai.   

Abstract

The interaction of blood with a material surface results in activation of the body's humoral immune system and the generation of reactive oxygen species (ROS). It has recently become clear that ROS are central to the pathology of many diseases. In this study, we evaluated the superoxide generation, permeation, and dismutation in hollow-fiber dialysis membranes by using 2-methyl-6-p-methoxyphenylethynyl-imidazopyrazinone (MPEC) as a superoxide-reactive chemiluminescence producer and an optical fiber probe to detect the resulting chemiluminescence in the hollow fiber lumen. We measured the superoxide generated when bovine blood leukocytes were brought into contact with dialysis membranes. Superoxide permeation was determined by measuring MPEC chemiluminescence in the hollow fiber lumen using an optical fiber probe. Additionally, superoxide dismutation was evaluated by examining the difference in superoxide permeability for membranes with and without vitamin E coating. Superoxide generation varies for different membrane materials, depending on the membrane's biocompatibility. Superoxide permeability depends on the diffusive permeability of membranes. No marked decrease in superoxide permeability was observed among membrane materials. The superoxide permeability of vitamin E-coated membrane was smaller than that of uncoated membrane. The antioxidant property of vitamin E-coated membranes is hence effective in causing superoxide dismutation.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16362524     DOI: 10.1007/s10047-005-0315-y

Source DB:  PubMed          Journal:  J Artif Organs        ISSN: 1434-7229            Impact factor:   1.385


  8 in total

Review 1.  Development of vitamin E-modified membrane.

Authors:  M Sasaki; N Hosoya; M Saruhashi
Journal:  Contrib Nephrol       Date:  1999       Impact factor: 1.580

2.  Vitamin E-coated dialyzer reduces oxidative stress in hemodialysis patients.

Authors:  G Clermont; S Lecour; J F Cabanne; G Motte; J C Guilland; D Chevet; L Rochette
Journal:  Free Radic Biol Med       Date:  2001-07-15       Impact factor: 7.376

3.  Hemodialysis impairs endothelial function via oxidative stress: effects of vitamin E-coated dialyzer.

Authors:  H Miyazaki; H Matsuoka; H Itabe; M Usui; S Ueda; S Okuda; T Imaizumi
Journal:  Circulation       Date:  2000-03-07       Impact factor: 29.690

4.  Prospective crossover trial of the influence of vitamin E-coated dialyzer membranes on T-cell activation and cytokine induction.

Authors:  M Girndt; S Lengler; H Kaul; U Sester; M Sester; H Köhler
Journal:  Am J Kidney Dis       Date:  2000-01       Impact factor: 8.860

5.  Vitamin E-bonded hemodialyzer improves atherosclerosis associated with a rheological improvement of circulating red blood cells.

Authors:  Shuzo Kobayashi; Hidekazu Moriya; Kuniko Aso; Takayasu Ohtake
Journal:  Kidney Int       Date:  2003-05       Impact factor: 10.612

6.  Evaluation of five imidazopyrazinone-type chemiluminescent superoxide probes and their application to the measurement of superoxide anion generated by Listeria monocytogenes.

Authors:  O Shimomura; C Wu; A Murai; H Nakamura
Journal:  Anal Biochem       Date:  1998-05-01       Impact factor: 3.365

7.  Effect of hemodialysis on total antioxidant capacity and serum antioxidants in patients with chronic renal failure.

Authors:  P Jackson; C M Loughrey; J H Lightbody; P T McNamee; I S Young
Journal:  Clin Chem       Date:  1995-08       Impact factor: 8.327

8.  A new method of determining the solute permeability of hollow-fiber dialysis membranes by means of laser lights traveling along optic fibers.

Authors:  T Ohmura; T Tatsuguchi; J Nishikido; T Yamamoto; F Fushimi; O Nishida; K Sakai
Journal:  ASAIO Trans       Date:  1989 Jul-Sep
  8 in total
  3 in total

1.  Effect of the addition of a labile gelatin component on the degradation and solute release kinetics of a stable PEG hydrogel.

Authors:  H Waldeck; W J Kao
Journal:  J Biomater Sci Polym Ed       Date:  2012-05-11       Impact factor: 3.517

2.  Development of a device for chemiluminescence determination of superoxide generated inside a dialysis hollow-fiber membrane.

Authors:  Takehito Ogawa; Sumire Koga; Taiji Yakushiji; Masato Matsuda; Ken-Ichiro Yamamoto; Hiroki Sakata; Makoto Fukuda; Takehiro Miyasaka; Kiyotaka Sakai
Journal:  J Artif Organs       Date:  2010-02-19       Impact factor: 1.731

3.  Blood cleaner on-chip design for artificial human kidney manipulation.

Authors:  N Suwanpayak; M A Jalil; M S Aziz; F D Ismail; J Ali; P P Yupapin
Journal:  Int J Nanomedicine       Date:  2011-05-02
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.