Literature DB >> 16360915

Effect of shorter polymerization times when using the latest generation of light-emitting diodes.

Y Teresa Silta1, William J Dunn, Charles B Peters.   

Abstract

INTRODUCTION: Recent studies have suggested that a 10-second cure time with a high-energy quartz-tungsten-halogen (QTH) or a light-emitting diode (LED) light might be adequate when bonding orthodontic brackets to tooth enamel. The purpose of this study was to evaluate the ability of the latest generation of QTH and LED light-curing units (LCUs) to bond orthodontic brackets to teeth at decreased polymerization times.
METHODS: Two LED LCUs (Ortholux LED, 3M Unitek, Monrovia, Calif; UltraLume LED 5, Ultradent Products, South Jordan, Utah) and a QTH LCU (Optilux 501, Demetron, Danbury, Conn) were evaluated. One hundred eighty metal orthodontic brackets were bonded to extracted human molars. The specimens were divided into 9 groups (3 lights and 3 curing times) of 20 teeth each. Each group was cured with 1 of the 3 lights for 20, 10, or 6 seconds. Thirty minutes after polymerization, the specimens were subjected to shear force on a universal testing machine until bracket failure.
RESULTS: Two-way ANOVA detected significant differences among the main effects of light type and cure time. Tukey post-hoc tests determined that brackets bonded by all light types had lower bond strengths with the 6-second cure than the 20-second cure (P < .001). The highest bond strengths were obtained with the Optilux 501 QTH LCU and the UltraLume LED 5 LCU at the longest cure time of 20 seconds.
CONCLUSIONS: It is recommended that orthodontic brackets be photopolymerized for at least 20 seconds with the QTH or the LED LCU before the archwires are engaged.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16360915     DOI: 10.1016/j.ajodo.2004.09.029

Source DB:  PubMed          Journal:  Am J Orthod Dentofacial Orthop        ISSN: 0889-5406            Impact factor:   2.650


  4 in total

1.  Efficiency of light-emitting diode and halogen units in reducing residual monomers.

Authors:  Felipe de Assis Ribeiro Carvalho; Rhita C Almeida; Marco Antonio Almeida; Lucia H S Cevidanes; Marcia C Amorim M Leite
Journal:  Am J Orthod Dentofacial Orthop       Date:  2010-11       Impact factor: 2.650

2.  Effect of short curing times with a high-intensity light-emitting diode or high-power halogen on shear bond strength of metal brackets before and after thermocycling.

Authors:  Erion Cerekja; Banu Cakirer
Journal:  Angle Orthod       Date:  2011-01-24       Impact factor: 2.079

3.  Clinical effect of reducing curing times with high-intensity LED lights.

Authors:  Justin D Ward; Bethany J Wolf; Luis P Leite; Jing Zhou
Journal:  Angle Orthod       Date:  2015-03-11       Impact factor: 2.079

4.  Debonding forces of three different customized bases of a lingual bracket system.

Authors:  Jang-Won Sung; Tae-Yub Kwon; Hee-Moon Kyung
Journal:  Korean J Orthod       Date:  2013-10-25       Impact factor: 1.372

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.