Literature DB >> 16359478

Clinical acceptability of crown margins versus marginal gaps as determined by pre-doctoral students and prosthodontists.

Michael R Bronson1, Terry J Lindquist, Deborah V Dawson.   

Abstract

PURPOSE: Marginal integrity is a very important element in evaluating a restoration; however, there is no agreement in definition of a clinically acceptable margin. The purpose of this investigation was to examine margin acceptability using an explorer versus the actual marginal gap widths at four locations on uncemented crowns on three extracted teeth using both predoctoral students and prosthodontists as evaluators.
MATERIALS AND METHODS: The crown margin evaluation used 16 surfaces of four crowns fitting to three extracted caries-free teeth fitted into a dentiform. The teeth (nos. 14, 20, and 29) were prepared for a full cast (gold) crown using a chamfer finish line configuration, with some margins supragingival and others subgingival. After final impressions and working casts were made, die spacer was applied to the marginal area of the die before waxing to vary the marginal opening. The dentiform was placed in a mannequin in a supine position. Predoctoral students (N = 10) and prosthodontists (N = 9) evaluated each axial surface of each crown in the zone along the margin with an explorer and rated each surface as either "clinically acceptable" or "unacceptable." After casting, the axial marginal openings were measured with Image Pro Software using a digital microscopic image of the surface. Each participant repeated the margin evaluations 6 months later.
RESULTS: Upon casting, marginal gaps ranged from 40 microm to 615 microm. The proportions of prosthodontists and of predoctoral students rating a given surface as "clinically unacceptable" were highly correlated (Spearman rank correlation = 0.81, p= 0.0001). The prosthodontists did not provide more or fewer ratings of clinical acceptability than the students, although kappa results indicated that the prosthodontists might be more consistent among themselves than the student raters. Upon re-evaluation, both groups rated between one and six of the surfaces differently than they had previously: the median number of inconsistencies was 1 for prosthodontists and 3 for predoctoral students. The prosthodontists tended to have fewer inconsistencies than the predoctoral students (0.05 < p < 0.10 Wilcoxon rank sum test), but this was not statistically significant.
CONCLUSION: The data provided evidence that those surfaces associated with greater margin gaps tended to have a greater proportion of ratings of "clinically unacceptable." The proportion of prosthodontists and predoctoral students rating a margin "clinically unacceptable" were highly correlated. Prosthodontists tended to have fewer inconsistencies than predoctoral students, but that difference was not statistically significant.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16359478     DOI: 10.1111/j.1532-849X.2005.00048.x

Source DB:  PubMed          Journal:  J Prosthodont        ISSN: 1059-941X            Impact factor:   2.752


  4 in total

1.  Comparative assessment of marginal accuracy of grade II titanium and Ni-Cr alloy before and after ceramic firing: An in vitro study.

Authors:  Abhijit Patil; Kishan Singh; Sukant Sahoo; Suraj Suvarna; Prince Kumar; Anupam Singh
Journal:  Eur J Dent       Date:  2013-07

2.  Method to evaluate the noise of 3D intra-oral scanner.

Authors:  Alban Desoutter; Osama Yusuf Solieman; Gérard Subsol; Hervé Tassery; Frédéric Cuisinier; Michel Fages
Journal:  PLoS One       Date:  2017-08-09       Impact factor: 3.240

3.  A comparative evaluation of the marginal adaptation of a thermoplastic resin, a light cured wax and an inlay casting wax on stone dies: An in vitro study.

Authors:  Reji P Gopalan; Vivek V Nair; K Harshakumar; R Ravichandran; S Lylajam; Prasanth Viswambaran
Journal:  J Indian Prosthodont Soc       Date:  2018 Jan-Mar

4.  In vitro validation of Digital Image Analysis Sequence (DIAS) for the assessment of the marginal fit of cement-retained implant-supported experimental crowns.

Authors:  Aristeidis A Villias; Stefanos G Kourtis; Hercules C Karkazis; Gregory L Polyzois
Journal:  Int J Implant Dent       Date:  2021-02-15
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.