Literature DB >> 16357647

The reliability of the Lanthony Desaturated D-15 test.

Gregory W Good1, Adrianne Schepler, Jason J Nichols.   

Abstract

PURPOSE: The Lanthony Desaturated Panel D-15 has been used to measure fine color discrimination for congenital and acquired color vision defects. This study investigated the test-retest reliability of the test using an intertest interval of approximately 1 month.
METHODS: One hundred twenty-six color vision normals (mean age = 34.5 years) were administered several color vision tests, including the Lanthony Desaturated D-15. Normal color vision status was confirmed using the anomaloscope and HRR color plates. The color vision tests were readministered 3 to 6 weeks after initial testing. The results of the Lanthony test were expressed using the color confusion index of Bowman. The difference in Color Confusion Index (CCI) between the two administrations was calculated and used to determine the intraclass correlation coefficient.
RESULTS: The overall mean CCI for the two administrations for these subjects was 1.11 +/- 0.136. The mean difference in CCI score between test administrations was -0.02 +/- 0.128. There was a strong correlation between the absolute value of the difference in CCI and the mean CCI for each subject (r = 0.51, p < 0.0001). The intraclass correlation coefficient was 0.56 (95% confidence interval, 0.43-0.67).
CONCLUSIONS: Although the Lanthony Desaturated D-15 test can be used to assess fine color discrimination, there is considerable within-subject variability in test results. The intraclass correlation coefficient is less than that recommended for use in clinical testing or research. Clinicians should consider at least three administrations of the test at each sitting to ensure precision and we recommend taking the mean of those three tests.

Entities:  

Mesh:

Year:  2005        PMID: 16357647     DOI: 10.1097/01.opx.0000192351.63069.4a

Source DB:  PubMed          Journal:  Optom Vis Sci        ISSN: 1040-5488            Impact factor:   1.973


  10 in total

1.  Association between retinal nerve fiber layer thickness and abnormalities of vision in people with human immunodeficiency virus infection.

Authors:  Partho S Kalyani; Gary N Holland; Amani A Fawzi; Tiago E F Arantes; Fei Yu; Alfredo A Sadun
Journal:  Am J Ophthalmol       Date:  2012-01-15       Impact factor: 5.258

2.  Age-corrected reference values for the Heidelberg multi-color anomaloscope.

Authors:  Florian Rüfer; Benno Sauter; Alexa Klettner; Katja Göbel; Josef Flammer; Carl Erb
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2012-02-17       Impact factor: 3.117

3.  Spatial contrast sensitivity: effects of reliability, test-retest repeatability and sample size using the Metropsis software.

Authors:  Thiago Paiva Fernandes; Natalia Leandro de Almeida; Pamela D Butler; Natanael Antonio Santos
Journal:  Eye (Lond)       Date:  2019-06-05       Impact factor: 3.775

4.  Cone function in children with a history of preterm birth.

Authors:  M Ecsedy; B Varsányi; A Szigeti; Gy Szrnka; J Németh; Zs Récsán
Journal:  Doc Ophthalmol       Date:  2011-04-01       Impact factor: 2.379

5.  Ethambutol ocular toxicity in a patient with pulmonary tuberculosis - a case report.

Authors:  Ak Tan; Ps Mallika; S Aziz; T Asok; G Intan
Journal:  Malays Fam Physician       Date:  2008-08-31

6.  Functional retinal outcomes in patients with prediabetes and type 2 diabetes.

Authors:  Nicole Karson; Jennyffer Smith; Morgan Jones; Ananya Datta; Kathryn Richdale; Wendy W Harrison
Journal:  Ophthalmic Physiol Opt       Date:  2020-09-21       Impact factor: 3.117

7.  Occupational styrene exposure, colour vision and contrast sensitivity: a cohort study with repeated measurements.

Authors:  Andreas Seeber; Thomas Bruckner; Gerhard Triebig
Journal:  Int Arch Occup Environ Health       Date:  2009-03-29       Impact factor: 3.015

8.  Colour discrimination thresholds in type 1 Bipolar Disorder: a pilot study.

Authors:  Thiago Monteiro Paiva Fernandes; Suellen Marinho Andrade; Michael Jackson Oliveira de Andrade; Renata Maria Toscano Barreto Lyra Nogueira; Natanael Antonio Santos
Journal:  Sci Rep       Date:  2017-11-27       Impact factor: 4.379

9.  Preliminary data for performance in hue ordering tests during pregnancy.

Authors:  T S S Calandrini; L Miquilini; M R Laranjeiras-Neto; M T S Tongu; M P Silva; G S Souza; M I T Cortes
Journal:  Braz J Med Biol Res       Date:  2019-01-24       Impact factor: 2.590

10.  A simple modification of the Farnsworth-Munsell 100-hue test for much faster assessment of color vision.

Authors:  Supriyo Ghose; Dinesh Shrey; Pradeep Venkatesh; Twinkle Parmar; Sourabh Sharma
Journal:  Indian J Ophthalmol       Date:  2014-06       Impact factor: 1.848