| Literature DB >> 16353978 |
Gareth Chaplin1, Todd Pugsley, Conrad Winters.
Abstract
Pressure fluctuation measurements collected during the fluidized bed granulation of pharmaceutical granule have been analyzed using the attractor comparison technique denoted as the S-statistic. Divergence of the bed state from the reference during granulation is followed by a return to a condition statistically similar to the original state of the dry fluidized ingredients on drying. This suggests insensitivity of the S-statistic technique to the changes in particle size distribution occurring during the granulation process. Consequently, the monitoring of pressure fluctuations alone may provide an easily implemented technique for the tracking of granule moisture and process end-point determination.Mesh:
Substances:
Year: 2005 PMID: 16353978 PMCID: PMC2750532 DOI: 10.1208/pt060229