Literature DB >> 16352437

A parallel approach to post source decay MALDI-TOF analysis.

D J Kenny1, J M Brown2, M E Palmer2, M F Snel2, R H Bateman2.   

Abstract

We present a novel enhancement to matrix-assisted laser desorption ionization (MALDI) post-source decay (PSD) analysis whereby fragment ions from multiple precursor ions are acquired into the same spectrum without employing a timed ion gate to preselect each parent ion. Fragment ions are matched to their corresponding precursor ions by comparing spectra acquired at slightly different reflectron electric fields. By measuring the difference in time-of-flight (TOF) between the two spectra for each fragment, it is possible to calculate the mass of the fragment ion and its parent. This new "parallel PSD" technique reduces analysis time and consumes less sample than conventional PSD, which requires an ion gate for serial preselection of precursor ions.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16352437     DOI: 10.1016/j.jasms.2005.09.006

Source DB:  PubMed          Journal:  J Am Soc Mass Spectrom        ISSN: 1044-0305            Impact factor:   3.109


  9 in total

Review 1.  Proteomics: the move to mixtures.

Authors:  J Peng; S P Gygi
Journal:  J Mass Spectrom       Date:  2001-10       Impact factor: 1.982

2.  Sequence dependent fragmentation of peptides generated by MALDI quadrupole time-of-flight (MALDI Q-TOF) mass spectrometry and its implications for protein identification.

Authors:  Andreas Wattenberg; Andrew J Organ; Klaus Schneider; Richard Tyldesley; Robert Bordoli; Robert H Bateman
Journal:  J Am Soc Mass Spectrom       Date:  2002-07       Impact factor: 3.109

3.  Rapid identification of proteins by peptide-mass fingerprinting.

Authors:  D J Pappin; P Hojrup; A J Bleasby
Journal:  Curr Biol       Date:  1993-06-01       Impact factor: 10.834

4.  Peptide sequencing by matrix-assisted laser-desorption mass spectrometry.

Authors:  B Spengler; D Kirsch; R Kaufmann; E Jaeger
Journal:  Rapid Commun Mass Spectrom       Date:  1992-02       Impact factor: 2.419

5.  Continuous sample deposition from reversed-phase liquid chromatography to tracks on a matrix-assisted laser desorption/ionization precoated target for the analysis of protein digests.

Authors:  Daniel B Wall; Scott J Berger; Jeffrey W Finch; Steven A Cohen; Keith Richardson; Richard Chapman; Darren Drabble; Jeffery Brown; Dominic Gostick
Journal:  Electrophoresis       Date:  2002-09       Impact factor: 3.535

6.  An approach to correlate tandem mass spectral data of peptides with amino acid sequences in a protein database.

Authors:  J K Eng; A L McCormack; J R Yates
Journal:  J Am Soc Mass Spectrom       Date:  1994-11       Impact factor: 3.109

7.  Identifying proteins from two-dimensional gels by molecular mass searching of peptide fragments in protein sequence databases.

Authors:  W J Henzel; T M Billeci; J T Stults; S C Wong; C Grimley; C Watanabe
Journal:  Proc Natl Acad Sci U S A       Date:  1993-06-01       Impact factor: 11.205

8.  Use of mass spectrometric molecular weight information to identify proteins in sequence databases.

Authors:  M Mann; P Højrup; P Roepstorff
Journal:  Biol Mass Spectrom       Date:  1993-06

9.  Protein identification by mass profile fingerprinting.

Authors:  P James; M Quadroni; E Carafoli; G Gonnet
Journal:  Biochem Biophys Res Commun       Date:  1993-08-31       Impact factor: 3.575

  9 in total
  2 in total

1.  High-Capacity Ion Trap Coupled to a Time-of-Flight Mass Spectrometer for Comprehensive Linked Scans with no Scanning Losses.

Authors:  Sunnie Myung; Herbert Cohen; David Fenyo; Julio C Padovan; Andrew N Krutchinsky; Brian T Chait
Journal:  Int J Mass Spectrom       Date:  2011-03-30       Impact factor: 1.986

2.  Imaging of lipids in spinal cord using intermediate pressure matrix-assisted laser desorption-linear ion trap/Orbitrap MS.

Authors:  Rachelle R Landgraf; Maria C Prieto Conaway; Timothy J Garrett; Peter W Stacpoole; Richard A Yost
Journal:  Anal Chem       Date:  2009-10-15       Impact factor: 6.986