Literature DB >> 1634943

Quantitative stress-redistribution thallium-201 SPECT using prone imaging: methodologic development and validation.

H Kiat1, K F Van Train, J D Friedman, G Germano, G Silagan, F P Wang, J Maddahi, F Prigent, D S Berman.   

Abstract

Prone 201Tl myocardial perfusion SPECT has been shown to improve left ventricular inferior wall counts compared to supine imaging, thus minimizing diaphragmatic attenuation. Prone SPECT quantitative normal limits were developed and prospectively applied to 36 patients who had coronary angiography. The prone imaging table used had a cut-out under cardiac area which increased the average myocardial counts by 10.7% compared to prone SPECT through the standard table. Overall specificity and sensitivity were 80% and 93%, respectively. For the right, left circumflex and left anterior descending coronary arteries, the specificities were 94%, 71%, and 94%; and sensitivities were 88%, 89% and 78%, respectively. The normalcy rate in 55 normal patients was 89%. Incidence and the severity of patients motion in 200 prone SPECT studies were compared to 200 supine SPECT studies. Mild and severe motion occurred in 12% and 4% of the supine studies and in only 3.5% and none of the prone studies, respectively. When compared to supine SPECT, prone SPECT had higher (p less than 0.01) regional counts/pixel in the inferior wall and septum, but required an average increase of 2.9 +/- 1.0 cm in camera to chest wall distance and resulted in a reduction of total myocardial counts. Prone SPECT provides an alternative approach for patients who cannot tolerate supine imaging. It should be considered when inferior wall defects on supine imaging pose a diagnostic dilemma and when motion on supine imaging necessitates repeat acquisition.

Entities:  

Mesh:

Substances:

Year:  1992        PMID: 1634943

Source DB:  PubMed          Journal:  J Nucl Med        ISSN: 0161-5505            Impact factor:   10.057


  36 in total

Review 1.  Effect of motion on cardiac SPECT imaging: recognition and motion correction.

Authors:  J Fitzgerald; P G Danias
Journal:  J Nucl Cardiol       Date:  2001 Nov-Dec       Impact factor: 5.952

2.  Supine-prone SPECT myocardial perfusion imaging: the poor man's attenuation compensation.

Authors:  Stephen A Stowers; Richard Umfrid
Journal:  J Nucl Cardiol       Date:  2003 May-Jun       Impact factor: 5.952

Review 3.  Diagnosis of coronary artery disease by radionuclide myocardial perfusion imaging.

Authors:  C Y Loong; C Anagnostopoulos
Journal:  Heart       Date:  2004-08       Impact factor: 5.994

4.  Single photon-emission computed tomography.

Authors:  Thomas A Holly; Brian G Abbott; Mouaz Al-Mallah; Dennis A Calnon; Mylan C Cohen; Frank P DiFilippo; Edward P Ficaro; Michael R Freeman; Robert C Hendel; Diwakar Jain; Scott M Leonard; Kenneth J Nichols; Donna M Polk; Prem Soman
Journal:  J Nucl Cardiol       Date:  2010-10       Impact factor: 5.952

5.  Myocardial perfusion and function single photon emission computed tomography.

Authors:  Christopher L Hansen; Richard A Goldstein; Daniel S Berman; Keith B Churchwell; C David Cooke; James R Corbett; S James Cullom; Seth T Dahlberg; James R Galt; Ravi K Garg; Gary V Heller; Mark C Hyun; Lynne L Johnson; April Mann; Benjamin D McCallister; Raymond Taillefer; R Parker Ward; John J Mahmarian
Journal:  J Nucl Cardiol       Date:  2006-11       Impact factor: 5.952

Review 6.  Myocardial perfusion and function: single photon emission computed tomography.

Authors:  Christopher L Hansen; Richard A Goldstein; Olakunle O Akinboboye; Daniel S Berman; Elias H Botvinick; Keith B Churchwell; C David Cooke; James R Corbett; S James Cullom; Seth T Dahlberg; Regina S Druz; Edward P Ficaro; James R Galt; Ravi K Garg; Guido Germano; Gary V Heller; Milena J Henzlova; Mark C Hyun; Lynne L Johnson; April Mann; Benjamin D McCallister; Robert A Quaife; Terrence D Ruddy; Senthil N Sundaram; Raymond Taillefer; R Parker Ward; John J Mahmarian
Journal:  J Nucl Cardiol       Date:  2007 Nov-Dec       Impact factor: 5.952

7.  Diagnostic accuracy of gated Tc-99m sestamibi stress myocardial perfusion SPECT with combined supine and prone acquisitions to detect coronary artery disease in obese and nonobese patients.

Authors:  Daniel S Berman; Xingping Kang; Hidetaka Nishina; Piotr J Slomka; Leslee J Shaw; Sean W Hayes; Ishac Cohen; John D Friedman; James Gerlach; Guido Germano
Journal:  J Nucl Cardiol       Date:  2006 Mar-Apr       Impact factor: 5.952

8.  Two-position supine/prone myocardial perfusion SPECT (MPS) imaging improves visual inter-observer correlation and agreement.

Authors:  Reza Arsanjani; Sean W Hayes; Mathews Fish; Aryeh Shalev; Rine Nakanishi; Louise E J Thomson; John D Friedman; Guido Germano; Daniel S Berman; Piotr Slomka
Journal:  J Nucl Cardiol       Date:  2014-05-08       Impact factor: 5.952

9.  Prognostic validation of a 17-segment score derived from a 20-segment score for myocardial perfusion SPECT interpretation.

Authors:  Daniel S Berman; Aiden Abidov; Xingping Kang; Sean W Hayes; John D Friedman; Maria G Sciammarella; Ishac Cohen; James Gerlach; Parker B Waechter; Guido Germano; Rory Hachamovitch
Journal:  J Nucl Cardiol       Date:  2004 Jul-Aug       Impact factor: 5.952

Review 10.  Morphology supporting function: attenuation correction for SPECT/CT, PET/CT, and PET/MR imaging.

Authors:  Tzu C Lee; Adam M Alessio; Robert M Miyaoka; Paul E Kinahan
Journal:  Q J Nucl Med Mol Imaging       Date:  2015-11-17       Impact factor: 2.346

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.