Literature DB >> 16344254

Dosimetric quantifiers for low-dose-rate prostate brachytherapy: is V(100) superior to D(90)?

Michael A Papagikos1, Allan F Deguzman, Peter J Rossi, David L McCullough, Peter E Clark, W Robert Lee.   

Abstract

PURPOSE: The purpose of the present report is to describe the relationship between two dosimetric quantifiers (V(100) and D(90)) and freedom from biochemical recurrence (FFBR) in a cohort of men treated with low-dose-rate prostate brachytherapy (LDRPB) alone. METHODS AND MATERIALS: One hundred three men were treated with LDRPB alone between September 1997 and December 1999. All men had histologically confirmed clinically localized prostate cancer. Fifty-nine percent of the cohort had low-risk disease (defined as PSA<10, Gleason <7, and T stage <T2b), and 41% had intermediate-risk disease (defined as PSA>/=10, Gleason>/=7, or T stage T2b). The prescription dose was 144Gy according to the Task Group 43 formalism. LDRPB was performed jointly by a radiation oncologist and a urologist. Dosimetric quantifiers (D(90), V(100)) were calculated from a CT scan performed 1 month after LDRPB. Biochemical recurrence was defined according to the ASTRO Consensus Definition. FFBR was estimated using the product-limit method. Disease-specific and treatment variables were examined as putative covariates for FFBR using the proportional hazards regression method. Univariate and multivariate methods were used. All p values are two sided.
RESULTS: The median followup for the entire cohort is 61 months. The median followup of patients at risk for biochemical failure is 66 months. The median D(90) is 129Gy (range 47-221Gy), and the median V(100) is 86% (range 51-99%). Thirteen men have developed evidence of biochemical relapse at a median of 25 months (range 6-42 months). The 5-year estimate of FFBR for the entire cohort is 87% (95% CI 80-94%). On univariate analysis, disease-specific variables found to be significantly associated with FFBR included pretreatment PSA and percent positive biopsies. When considered as a continuous variable, each of the dosimetric quantifiers was associated with FFBR (V(100): p=0.007; D(90): p=0.05). D'Amico risk group classification is highly predictive of FFBR after LDRPB (HR 5.68, p=0.003). Multivariate analysis indicated that each dosimetric quantifier was independently associated with FFBR, but due to the high degree of correlation (Pearson correlation coefficient 0.94, p<0.0001) between the dosimetric quantifiers both could not be included simultaneously in the model. In the two models explored, V(100) was at least as good as D(90) in predicting FFBR.
CONCLUSIONS: Dosimetric quantifiers (V(100) and D(90)) are independent predictors of FFBR after treatment with LDRPB alone. In our experience, V(100) seems to be at least equivalent (and perhaps superior) to D(90) for predicting FFBR.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16344254     DOI: 10.1016/j.brachy.2005.09.001

Source DB:  PubMed          Journal:  Brachytherapy        ISSN: 1538-4721            Impact factor:   2.362


  9 in total

1.  Fused radioimmunoscintigraphy for treatment planning.

Authors:  Rodney J Ellis; Deborah A Kaminsky
Journal:  Rev Urol       Date:  2006

2.  Evaluation of interobserver differences in postimplant dosimetry following prostate brachytherapy and the efficacy of CT/MRI fusion imaging.

Authors:  Manabu Aoki; Atsunori Yorozu; Takushi Dokiya
Journal:  Jpn J Radiol       Date:  2009-11-27       Impact factor: 2.374

3.  Permanent prostate brachytherapy postimplant magnetic resonance imaging dosimetry using positive contrast magnetic resonance imaging markers.

Authors:  Geoffrey V Martin; Thomas J Pugh; Usama Mahmood; Rajat J Kudchadker; Jihong Wang; Teresa L Bruno; Tharakeswara Bathala; Pierre Blanchard; Steven J Frank
Journal:  Brachytherapy       Date:  2017-05-10       Impact factor: 2.362

4.  Statin use is associated with decreased prostate cancer recurrence in men treated with brachytherapy.

Authors:  Daniel S Oh; Bridget Koontz; Stephen J Freedland; Leah Gerber; Pretesh Patel; Stephen Lewis; David S Yoo; James Oleson; Joseph K Salama
Journal:  World J Urol       Date:  2014-03-27       Impact factor: 4.226

5.  Prostate deformation from inflatable rectal probe cover and dosimetric effects in prostate seed implant brachytherapy.

Authors:  Jun Lian; Yeqin Shao; Larry D Potter; Ronald C Chen; Jordan A Holmes; Eleanor A Pryser; Jie Shen; Dinggang Shen; Andrew Z Wang
Journal:  Med Phys       Date:  2016-12       Impact factor: 4.071

6.  Comparison of post-implant dosimetrics between intraoperatively built custom-linked seeds and loose seeds by sector analysis at 24 hours and 1 month for localized prostate cancer.

Authors:  Eiichiro Okazaki; Katsuyuki Kuratsukuri; Tomohiro Nishikawa; Tomoaki Tanaka; Mai Sakagami; Keiko Shibuya
Journal:  J Contemp Brachytherapy       Date:  2020-08-21

7.  Preoperative treatment planning with intraoperative optimization can achieve consistent high-quality implants in prostate brachytherapy.

Authors:  Rajat J Kudchadker; Thomas J Pugh; David A Swanson; Teresa L Bruno; Yasemin Bolukbasi; Steven J Frank
Journal:  Med Dosim       Date:  2012-05-03       Impact factor: 1.482

8.  Pre-plan parameters predict post-implant D90 ≥ 140 Gy for (125)I permanent prostate implants.

Authors:  Jes Alexander; Vivian Weinberg; Alexander R Gottschalk; I-Chow Joe Hsu; Katsuto Shinohara; Mack Roach
Journal:  J Contemp Brachytherapy       Date:  2014-06-03

9.  Correlations of post-implant regional dosimetric parameters at 24 hours and one month, with clinical results of low-dose-rate brachytherapy for localized prostate cancer.

Authors:  Eiichiro Okazaki; Katsuyuki Kuratsukuri; Kentaro Ishii; Tomoaki Tanaka; Ryo Ogino; Tomohiro Nishikawa; Hideyuki Morimoto; Masako Hosono; Yukio Miki
Journal:  J Contemp Brachytherapy       Date:  2017-12-30
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.