Literature DB >> 16344123

3-D measurement of body tissues based on ultrasound images with 3-D spatial information.

Qing-Hua Huang1, Yong-Ping Zheng, Robert Li, Min-Hua Lu.   

Abstract

In this study, we developed a new method to perform 3-D measurements between the recorded B-scans using the corresponding spatial location and orientation of each B-scan, without the need to create a 3-D volume. A portable ultrasound (US) scanner and an electromagnetic spatial locator attached to the US probe were used. During data collection, the US probe was moved over the region-of-interest. A small number of B-scans containing interesting anatomical information were captured from different body parts and displayed in a 3-D space with their corresponding locations recorded by the spatial locator. In the B-scan planes, the distance between any two points, as well as the angle between any two lines, could be calculated. In validation experiments, three distances and three angles of a custom-designed phantom were measured using this method. In comparison with the results measured by a micrometer, the mean error of distance measurement was -0.8 +/- 1.7 mm (-2.3 +/- 3.6%) and that of angle measurement was -0.3 +/- 2.9 degrees (-0.1 +/- 4.1%). The lengths of the first metatarsals and the angles between the first metatarsals and the middle part of the tibias of three subjects were measured in vivo using magnetic resonance imaging (MRI) and the US method by two operators before and after MRI scanning. The overall percentage differences of the length and angle measurements were 0.8 +/- 2.2% and 2.5 +/- 3.6%, respectively. The results showed that this US method had good repeatability and reproducibility (interclass correlation coefficient values > 0.75). We expect that this new method could potentially provide a quick and effective approach for the 3-D measurement of soft tissues and bones in the musculoskeletal system.

Mesh:

Year:  2005        PMID: 16344123     DOI: 10.1016/j.ultrasmedbio.2005.08.004

Source DB:  PubMed          Journal:  Ultrasound Med Biol        ISSN: 0301-5629            Impact factor:   2.998


  2 in total

1.  Validation of Scolioscan Air-Portable Radiation-Free Three-Dimensional Ultrasound Imaging Assessment System for Scoliosis.

Authors:  Kelly Ka-Lee Lai; Timothy Tin-Yan Lee; Michael Ka-Shing Lee; Joseph Chi-Ho Hui; Yong-Ping Zheng
Journal:  Sensors (Basel)       Date:  2021-04-19       Impact factor: 3.576

2.  A reliability and validity study for Scolioscan: a radiation-free scoliosis assessment system using 3D ultrasound imaging.

Authors:  Yong-Ping Zheng; Timothy Tin-Yan Lee; Kelly Ka-Lee Lai; Benjamin Hon-Kei Yip; Guang-Quan Zhou; Wei-Wei Jiang; James Chung-Wai Cheung; Man-Sang Wong; Bobby King-Wah Ng; Jack Chun-Yiu Cheng; Tsz-Ping Lam
Journal:  Scoliosis Spinal Disord       Date:  2016-05-31
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.