Literature DB >> 16340091

A fluoroscopy-based surgical navigation system for high tibial osteotomy.

Gongli Wang1, Guoyan Zheng, Paul Alfred Gruetzner, Urs Mueller-Alsbach, Jan von Recum, Alex Staubli, Lutz-Peter Nolte.   

Abstract

High tibial osteotomy is a widely accepted treatment for unicompartmental osteoarthritis of the knee and other lower extremity deformities, particularly in young and active patients. However, it is generally recognized as a technically demanding procedure. The lack of intraoperative control of the mechanical axis of the affected limb often results in postoperative malalignments, which is one of the main reasons for poor long-term results. Moreover, inaccurate osteotomies, such as insufficient or excessive bone cut, or incorrect orientation of the chisel or saw blade, have been observed. A computer assisted intraoperative planning and navigation system is therefore proposed in order to address these technical problems. During operation, fluoroscopic images are acquired and anatomical landmarks are digitized; a patient-specific coordinate system is established accordingly. After the three-dimensional measurement of the deformity and interactive planning of the osteotomy plane, the deformity is corrected under navigational guidance. The proposed system has been successfully introduced into the clinical practice of surgery after encouraging laboratory evaluations, with results affirming that it is safe and accurate.

Entities:  

Mesh:

Year:  2005        PMID: 16340091

Source DB:  PubMed          Journal:  Technol Health Care        ISSN: 0928-7329            Impact factor:   1.285


  5 in total

Review 1.  [Precision in orthopaedic computer navigation].

Authors:  T Hüfner; D Kendoff; M Citak; J Geerling; C Krettek
Journal:  Orthopade       Date:  2006-10       Impact factor: 1.087

2.  Heterotopic ossification post navigated high tibial osteotomy.

Authors:  Mustafa Citak; Daniel Kendoff; Padhraig F O'Loughlin; Andrew D Pearle
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2008-11-26       Impact factor: 4.342

3.  Radiographic markers for measuring tibial rotation based on CT-reconstructed radiographs: an accuracy and feasibility study.

Authors:  David Hakimian; Amal Khoury; Rami Mosheiff; Meir Liebergall; Yoram A Weil
Journal:  Skeletal Radiol       Date:  2017-11-11       Impact factor: 2.199

4.  Influence of lower limb rotation in navigated alignment analysis: implications for high tibial osteotomies.

Authors:  D Kendoff; M Citak; A Pearle; M J Gardner; S Hankemeier; C Krettek; T Hüfner
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2007-03-16       Impact factor: 4.342

5.  Computer-assisted navigation in high tibial osteotomy: a systematic review of the literature.

Authors:  Natasha E Picardo; Wasim Khan; David Johnstone
Journal:  Open Orthop J       Date:  2012-07-27
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.