Literature DB >> 16336797

[Reduction of lymphatic drainage posterior to modified radical mastectomy with the application of fibrin glue].

José Luis Segura-Castillo1, Oscar Estrada-Rivera, Juan Manuel Castro-Cervantes, Ana Olivia Cortés-Flores, Gabriela Abigail Velázquez-Ramírez, Alejandro González-Ojeda.   

Abstract

OBJECTIVE: Our objective was to investigate the effectiveness of fibrin glue to reduce hemato-lymphatic fluid production after modified radical mastectomy (MRM) in women with breast cancer.
MATERIAL AND METHODS: A total of 43 women treated surgically were randomly assigned to receive 10 ml of fibrin glue at the end of the breast resection plus closed suction drains (n = 22), or drain system only as a control group (n = 23). Outcome variables were fluid collected in the drainage system measured each 24 h. Drains were removed when a 50 ml output per day was obtained. Seroma formation and flap complications were also investigated.
RESULTS: The average age was 48.36 +/- 8.9 years for the study group and 52.87 +/- 9.74 years for the control group (p = 0.11). Body mass index (BMI) ranged between 22 and 35 kg/m2: 28.1 +/- 2.7 vs. 29.92 +/- 4.0 kg/m2 (p = 0.27). A reduction of the fluid drained was observed from the first postoperative day in the study group in contrast with the control (174.55 +/- 64.69 vs. 281.22 +/- 116.91, p = 0.001). A correlation between the BMI and the exposed surgical area was also statistically significant (p < 0.002), as well as the day the drains were extracted (p < 0.05). The incidence of seroma formation was 9% in the study group and 34.78% in the control, a statistically significant finding (p < 0.05).
CONCLUSIONS: Fibrin glue locally applied to the surgical wound under the flap and axilla significantly reduced the amount and duration of lymphatic fluid produced after MRM with axillary dissection. Also, a significant reduction in the incidence of seromas was observed.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16336797

Source DB:  PubMed          Journal:  Cir Cir        ISSN: 0009-7411            Impact factor:   0.361


  6 in total

1.  Effects of Fibrin Sealant on Seroma Reduction for Patients with Breast Cancer Undergoing Axillary Dissection: Meta-Analysis of Randomized Controlled Trials.

Authors:  Ya-Ting Chang; Shen-Liang Shih; El-Wui Loh; Ka-Wai Tam
Journal:  Ann Surg Oncol       Date:  2020-06-20       Impact factor: 5.344

2.  Is it really useful the Harmonic scalpel in axillary dissection for locally advanced breast cancer? A case series.

Authors:  G Militello; P De Marco; N Falco; K Kabhuli; A Mascolino; L Licari; R Tutino; G Cocorullo; G Gulotta
Journal:  G Chir       Date:  2016 Nov-Dec

Review 3.  Fibrin glue instillation under skin flaps to prevent seroma-related morbidity following breast and axillary surgery.

Authors:  Muhammad S Sajid; Kristian H Hutson; Ignazio F Rapisarda; Riccardo Bonomi
Journal:  Cochrane Database Syst Rev       Date:  2013-05-31

4.  The effect of fibrin glue on the postoperative lymphatic leakage after D2-lymphadenectomy and gastrectomy in patients with gastric cancer.

Authors:  Habibollah Mahmoodzadeh; Ehsanollah Rahimi-Movaghar; Ramesh Omranipour; Mohammad Shirkhoda; Amirmohsen Jalaeefar; Seyed Rouhollah Miri; Amirsina Sharifi
Journal:  BMC Surg       Date:  2021-03-21       Impact factor: 2.102

5.  Seroma formation after breast cancer surgery: what we have learned in the last two decades.

Authors:  Vivek Srivastava; Somprakas Basu; Vijay Kumar Shukla
Journal:  J Breast Cancer       Date:  2012-12-31       Impact factor: 3.588

6.  Harmonic Scalpel versus Electrocautery Dissection in Modified Radical Mastectomy for Breast Cancer: A Meta-Analysis.

Authors:  Jinbo Huang; Yinghua Yu; Changyuan Wei; Qinghong Qin; Qinguo Mo; Weiping Yang
Journal:  PLoS One       Date:  2015-11-06       Impact factor: 3.240

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.