Literature DB >> 16335169

A preliminary prospective evaluation of all-ceramic crown-retained and inlay-retained fixed partial dentures.

Stefan Wolfart1, Frank Bohlsen, Stefan Martin Wegner, Matthias Kern.   

Abstract

PURPOSE: The purpose of this preliminary prospective study was to evaluate the clinical outcome of crown-retained and inlay-retained fixed partial dentures (FPDs) made from a new lithium-disilicate glass-ceramic (IPS e.max Press, Ivoclar Vivadent).
MATERIALS AND METHODS: Eighty-one 3-unit FPDs were placed in 68 patients. The FPDs replaced teeth in the anterior (8%) and posterior region (92%). All teeth were prepared according to a standardized protocol. The size of the proximal connector of the FPDs was 12 mm2 (anterior) or 16 mm2 (posterior), respectively. Crown-retained FPDs were cemented either with glass ionomer (n = 20) or resin composite (n = 16), while all inlay-retained FPDs (n = 45) were cemented with resin composite. Initial follow-up was performed at 6 and 12 months and annually thereafter.
RESULTS: The mean observation periods were 48 months (for crown-retained FPDs) and 37 months (for inlay-retained FPDs). None of the crown-retained FPDs failed during the observation period, while 6 inlay-retained FPDs (13%) had to be replaced. Six cases failed because of debonding (n = 3) or a combination of debonding and fracture (n = 3). During the observation period, 2 patients died and the status of another 5 patients is unknown. The 4-year survival rate according to Kaplan-Meier was 100% for crown-retained FPDs and 89% for inlay-retained FPDs. The differences between the groups were statistically significant.
CONCLUSION: Crown-retained 3-unit FPDs made from a new glass-ceramic have a significantly better outcome up to 5 years than inlay-retained 3-unit FPDs over the observation period.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16335169

Source DB:  PubMed          Journal:  Int J Prosthodont        ISSN: 0893-2174            Impact factor:   1.681


  7 in total

Review 1.  Recent advances in materials for all-ceramic restorations.

Authors:  Jason A Griggs
Journal:  Dent Clin North Am       Date:  2007-07

2.  Impact Behavior of Three Notched All-Ceramic Restorations after Soaking in Artificial Saliva.

Authors:  Min Yan; Chung-Kai Wei; Yuh-Yih Lin; Suh-Woan Hu; Shinn-Jyh Ding
Journal:  Materials (Basel)       Date:  2015-07-20       Impact factor: 3.623

3.  Effect of temporary cements on the shear bond strength of luting cements.

Authors:  Marco Fiori-Júnior; Wilson Matsumoto; Raquel Assed Bezerra Silva; Sizenando Toledo Porto-Neto; Jaciara Miranda Gomes Silva
Journal:  J Appl Oral Sci       Date:  2010 Jan-Feb       Impact factor: 2.698

4.  Fracture toughness of zirconia with a nanometer size notch fabricated using focused ion beam milling.

Authors:  Yifeng Liao; Max Gruber; Henry Lukic; Si Chen; Spiro Megremis
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2020-06-20       Impact factor: 3.368

Review 5.  Tooth wear against ceramic crowns in posterior region: a systematic literature review.

Authors:  Rim Hmaidouch; Paul Weigl
Journal:  Int J Oral Sci       Date:  2013-10-18       Impact factor: 6.344

6.  Inlay-retained fixed dental prosthesis: a clinical option using monolithic zirconia.

Authors:  Davide Augusti; Gabriele Augusti; Andrea Borgonovo; Massimo Amato; Dino Re
Journal:  Case Rep Dent       Date:  2014-05-21

Review 7.  A systematic review of outcome measurements and quality of studies evaluating fixed tooth-supported restorations.

Authors:  Devangkumar Rajnikant Patel; Tim O'Brien; Aviva Petrie; Haralampos Petridis
Journal:  J Prosthodont       Date:  2014-06-19       Impact factor: 2.752

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.