Decoupling initial electron beam parameters for Monte Carlo photon beam modelling by removing beam-modifying filters from the beam path.

B De Smedt1, N Reynaert, F Flachet, M Coghe, M G Thompson, L Paelinck, G Pittomvils, C De Wagter, W De Neve, H Thierens.   

Abstract

A new method is presented to decouple the parameters of the incident e(-) beam hitting the target of the linear accelerator, which consists essentially in optimizing the agreement between measurements and calculations when the difference filter, which is an additional filter inserted in the linac head to obtain uniform lateral dose-profile curves for the high energy photon beam, and flattening filter are removed from the beam path. This leads to lateral dose-profile curves, which depend only on the mean energy of the incident electron beam, since the effect of the radial intensity distribution of the incident e- beam is negligible when both filters are absent. The location of the primary collimator and the thickness and density of the target are not considered as adjustable parameters, since a satisfactory working Monte Carlo model is obtained for the low energy photon beam (6 MV) of the linac using the same target and primary collimator. This method was applied to conclude that the mean energy of the incident e- beam for the high energy photon beam (18 MV) of our Elekta SLi Plus linac is equal to 14.9 MeV. After optimizing the mean energy, the modelling of the filters, in accordance with the information provided by the manufacturer, can be verified by positioning only one filter in the linac head while the other is removed. It is also demonstrated that the parameter setting for Bremsstrahlung angular sampling in BEAMnrc ('Simple' using the leading term of the Koch and Motz equation or 'KM' using the full equation) leads to different dose-profile curves for the same incident electron energy for the studied 18 MV beam. It is therefore important to perform the calculations in 'KM' mode. Note that both filters are not physically removed from the linac head. All filters remain present in the linac head and are only rotated out of the beam. This makes the described method applicable for practical usage since no recommissioning process is required.

Entities:  

Mesh:

Year:  2005        PMID: 16333165     DOI: 10.1088/0031-9155/50/24/012

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  3 in total

1.  Determination of electron energy, spectral width, and beam divergence at the exit window for clinical megavoltage x-ray beams.

Authors:  D L Sawkey; B A Faddegon
Journal:  Med Phys       Date:  2009-03       Impact factor: 4.071

2.  Benchmarking of Monte Carlo simulation of bremsstrahlung from thick targets at radiotherapy energies.

Authors:  Bruce A Faddegon; Makoto Asai; Joseph Perl; Carl Ross; Josep Sempau; Jane Tinslay; Francesc Salvat
Journal:  Med Phys       Date:  2008-10       Impact factor: 4.071

3.  Simulation of large x-ray fields using independently measured source and geometry details.

Authors:  D Sawkey; B A Faddegon
Journal:  Med Phys       Date:  2009-12       Impact factor: 4.071