A titanium-encased alumina ceramic bearing for total hip arthroplasty: 3- to 5-year results.

James A D'Antonio1, William N Capello, Michael T Manley, Marybeth Naughton, Kate Sutton.   

Abstract

UNLABELLED: We examined whether encasing the alumina ceramic total hip arthroplasty insert in a thin titanium sleeve would reduce significantly or eliminate insert chipping on impaction of the insert into the shell. We also compared results, including observations of osteolysis, of the Trident study group with those of the predecessor alumina bearing couple design to determine clinical improvement and radiographic stability. Beginning in October 1996, 328 alumina ceramic bearings were implanted by six surgeons in 316 patients as a part of a prospective, randomized United States Investigational Device Exemption three-arm study comparing an alumina ceramic bearing with a control bearing of cobalt-chromium on polyethylene. In September 1999, a fourth arm of the study (Trident) was added. The Trident insert was recessed within a thin titanium sleeve. At three to five years followup, osteolysis was found in 0% of the patients with the Trident insert and in 0.5% of the patients with an alumina bearing couple. At a mean followup of 4.2 years (range, 3-5 years) no ceramic chips, fractures, or ceramic bearing failures have occurred. Encasing the alumina ceramic insert in a titanium sleeve seems to have resolved the issue of insert chipping on impaction and supports the continued use of Trident bearings in relatively young patients. LEVEL OF EVIDENCE: Therapeutic study, Level II-1 (prospective comparative study-patients treated one way compared with a group of patients treated in another way at the same institution). See the Guidelines for Authors for a complete description of levels of evidence.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16330998     DOI: 10.1097/01.blo.0000194084.67364.6c

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  13 in total

1.  Incidence of ceramic liner malseating in Trident acetabular shell.

Authors:  Anna N Miller; Edwin P Su; Mathias P G Bostrom; Bryan J Nestor; Douglas E Padgett
Journal:  Clin Orthop Relat Res       Date:  2009-03-12       Impact factor: 4.176

2.  Comparative effectiveness of ceramic-on-ceramic implants in stemmed hip replacement: a multinational study of six national and regional registries.

Authors:  Art Sedrakyan; Stephen Graves; Barbara Bordini; Miquel Pons; Leif Havelin; Susan Mehle; Elizabeth Paxton; Thomas Barber; Guy Cafri
Journal:  J Bone Joint Surg Am       Date:  2014-12-17       Impact factor: 5.284

3.  Suboptimal Component Position Leading to Severe Wear of an Alumina-Alumina Total Hip Coupling: Biomechanical Analysis and Documentation of Limited Tissue Response.

Authors:  Jaime A Carvajal Alba; Marcella E Elpers; Andrew E Rosenberg; Raymond P Robinson
Journal:  HSS J       Date:  2015-05-27

4.  High survivorship with a titanium-encased alumina ceramic bearing for total hip arthroplasty.

Authors:  James A D'Antonio; William N Capello; Marybeth Naughton
Journal:  Clin Orthop Relat Res       Date:  2014-02       Impact factor: 4.176

5.  Ceramic liner fracture and impingement in total hip arthroplasty.

Authors:  Amy Steinhoff; Victor Hakim; Richard H Walker; Clifford W Colwell; Steven N Copp
Journal:  HSS J       Date:  2014-10-21

6.  Does acetabular inclination angle affect survivorship of alumina-ceramic articulations?

Authors:  Henning R Johansson; Aaron J Johnson; Michael G Zywiel; Marybeth Naughton; Michael A Mont; Peter M Bonutti
Journal:  Clin Orthop Relat Res       Date:  2011-06       Impact factor: 4.176

7.  Сomparative analysis of large diameter bearing ceramic monoblock acetabular components.

Authors:  Valery Yu Murylev; Pavel M Elizarov; Aleksei V Muzychenkov; Yaroslav A Rukin; Grigory A Kukovenko; Semen S Alekseev; Michail P Elizarov
Journal:  J Orthop       Date:  2022-08-11

8.  Incidence of 'squeaking' after ceramic-on-ceramic total hip arthroplasty.

Authors:  Kenny Mai; Christopher Verioti; Kace A Ezzet; Steven N Copp; Richard H Walker; Clifford W Colwell
Journal:  Clin Orthop Relat Res       Date:  2010-02       Impact factor: 4.176

Review 9.  Comparative assessment of implantable hip devices with different bearing surfaces: systematic appraisal of evidence.

Authors:  Art Sedrakyan; Sharon-Lise T Normand; Stefan Dabic; Samantha Jacobs; Stephen Graves; Danica Marinac-Dabic
Journal:  BMJ       Date:  2011-11-29

10.  Alumina ceramic-on-ceramic hybrid total hip arthroplasty. A median of 15 years follow-up.

Authors:  Omer M H Farhan-Alanie; Alex Hrycaiczuk; Craig Tinning; Bryn Jones; Andrew Stark; Kevin Bryceland
Journal:  Eur J Orthop Surg Traumatol       Date:  2021-08-06
View more