Literature DB >> 16329781

Sample preparation followed by high performance liquid chromatographic (HPLC) analysis for monitoring muconic acid as a biomarker of occupational exposure to benzene.

Seyed Jamaleddin Shahtaheri1, Farhad Ghamari, Farideh Golbabaei.   

Abstract

Factors affecting solid phase extraction (SPE) of trans,trans-muconic acid (ttMA), as a benzene biomarker, including sample pH, sample concentration, sample volume, sample flow rate, washing solvent, elution solvent, and type of sorbent were evaluated. Extracted samples were determined by HPLC-UV (high performance liquid chromatography-ultraviolet). The analytical column was C18, UV wave length was 259 nm, and the mobile phase was H(2)O/methanol/acetic acid run at flow rate of 1 ml/min. A strong anion exchange silica cartridge was found successful in simplifying SPE. There was a significant difference between recoveries of ttMA when different factors were used (p < .001). An optimum recovery was obtained when sample pH was adjusted at 7. There was no significant difference when different sample concentrations were used (p > .05). The optimized method was then validated with 3 different pools of samples showing good reproducibility over 6 consecutive days and 6 within-day experiments.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16329781     DOI: 10.1080/10803548.2005.11076658

Source DB:  PubMed          Journal:  Int J Occup Saf Ergon        ISSN: 1080-3548


  6 in total

Review 1.  The use of biomonitoring data in exposure and human health risk assessment: benzene case study.

Authors:  Scott M Arnold; Juergen Angerer; Peter J Boogaard; Michael F Hughes; Raegan B O'Lone; Steven H Robison; A Robert Schnatter
Journal:  Crit Rev Toxicol       Date:  2013-02       Impact factor: 5.635

Review 2.  Benzene exposure: an overview of monitoring methods and their findings.

Authors:  Clifford P Weisel
Journal:  Chem Biol Interact       Date:  2010-01-06       Impact factor: 5.192

3.  Solid phase extraction for monitoring of occupational exposure to Cr (III).

Authors:  S J Shahtaheri; M Khadem; F Golbabaei; A Rahimi-Froushani
Journal:  Anal Chem Insights       Date:  2007-12-11

4.  Coupling of Molecular Imprinted Polymer Nanoparticles by High Performance Liquid Chromatography as an Efficient Technique for Sensitive and Selective Trace Determination of 4-Chloro-2-Methylphenoxy Acetic Acid in Complex Matrices.

Authors:  Fariborz Omidi; Mohammad Behbahani; Saadi Samadi; Alireza Sedighi; Seyed Jamaleddin Shahtaheri
Journal:  Iran J Public Health       Date:  2014-05       Impact factor: 1.429

5.  A Simple and Fast Method Based on New Magnetic Ion Imprinted Polymer as a Highly Selective Sorbent for Preconcentration and Determination of Cadmium in Environmental Samples.

Authors:  Zahra Panjali; Ali Akbar Asgharinezhad; Homeira Ebrahimzadeh; Niloofar Jalilian; Rasoul Yarahmadi; Seyed Jamaleddin Shahtaheri
Journal:  Iran J Public Health       Date:  2016-08       Impact factor: 1.429

6.  Development of Hollow-Fiber Liquid-Phase Microextraction Method for Determination of Urinary trans,trans-Muconic Acid as a Biomarker of Benzene Exposure.

Authors:  Farhad Ghamari; Abdulrahman Bahrami; Yadollah Yamini; Farshid Ghorbani Shahna; Abbas Moghimbeigi
Journal:  Anal Chem Insights       Date:  2016-09-11
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.