A comparison of higher order aberrations following implantation of four foldable intraocular lens designs.

Robert G Martin1, Donald R Sanders.   

Abstract

PURPOSE: To determine the higher order aberrations following implantation of four foldable intraocular lens (IOL) designs.
METHODS: One hundred twenty-two eyes were randomly assigned to undergo implantation with one of four foldable IOL designs--Collamer (STAAR Surgical, Monrovia, Calif), plate haptic silicone (STAAR Surgical), AcrySof (Alcon, Ft Worth, Tex), or the Sensar (Advanced Medical Optics, Santa Ana, Calif). All enrolled eyes underwent wavefront assessment using the Tracey Visual Function Analyzer (Tracey Technologies, Houston, Tex).
RESULTS: Preoperatively, no significant differences were noted in higher order aberrations between the four lens groups. No significant differences were noted among the plate haptic silicone, Sensar, or AcrySof lenses at 1 week or 1 month postoperatively, or among the Collamer, plate haptic silicone, or Sensar lenses, with regard to total higher order aberrations, although differences were observed in individual aberration terms. At 1 week and 1 month postoperatively, the Collamer IOL had significantly less higher order aberrations than the AcrySof lens (P < .01). Significantly less third and fourth order aberrations, coma, trefoil, spherical aberration, and tetrafoil were observed postoperatively with the Collamer than the AcrySof IOL. There were no parameters where the AcrySof had significantly less optical aberrations than the Collamer.
CONCLUSIONS: The Collamer IOL design is associated with fewer higher order aberrations than the AcrySof lens.

Entities:  

Mesh:

Year:  2005        PMID: 16329364     DOI: 10.3928/1081-597X-20051101-10

Source DB:  PubMed          Journal:  J Refract Surg        ISSN: 1081-597X            Impact factor:   3.573


  2 in total

1.  Comparing the effect of two different intraocular lenses on optical aberrations in bilaterally operated eyes for cataract.

Authors:  Esra Ayhan Tuzcu; Kuddusi Erkilic; Betul Bulut; Nilufer Ilhan
Journal:  Pak J Med Sci       Date:  2013-07       Impact factor: 1.088

2.  Effect of Implantable Collamer Lens on Anterior Segment Measurement and Intraocular Lens Power Calculation Based on IOLMaster 700 and Sirius.

Authors:  Xiaoyong Chen; Di Zhang; Ziyuan Liu; Yinan Liu; Hongyuan Cai; Qianru Wu; Yu Zhang
Journal:  J Ophthalmol       Date:  2021-12-21       Impact factor: 1.909

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.