Literature DB >> 16325386

An immunosensor for ferritin based on agarose hydrogel.

Xiuhua Zhang1, Shengfu Wang, Mei Hu, Yao Xiao.   

Abstract

A novel electrochemical immunosensor for determination of ferritin in serum has been proposed. The immunosensor was prepared by immobilizing ferritin antibody (FeAb) on a glassy carbon electrode (GCE) based on agarose hydrogel. The modification procedure of the immunosensor was characterized by cyclic voltammetry (CV) and differential pulse voltammetry (DPV). The effects of amount of FeAb, incubation time and temperature on the immunosensor were explored to provide optimum analytical performance. The determination of ferritin was based on the change in DPV response before and after the antibody (Ab)-antigen (Ag) reaction. Tests result indicated that FeAb in the device microenvironment had biological activity. The detection limit for ferritin was 1.5 x 10(-5) g l(-1) and the linear range was 5-50 x 10(-5) g l(-1) with a correlation coefficient of 0.996. The storage stability was acceptable in pH 7.0 phosphate buffer saline (PBS) solution at 4 degrees C for 10 days. The proposed immunosensor provides a new promising method for the clinical immunoassay of ferritin.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16325386     DOI: 10.1016/j.bios.2005.10.018

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  6 in total

1.  Location of biomarkers and reagents within agarose beads of a programmable bio-nano-chip.

Authors:  Jesse V Jokerst; Jie Chou; James P Camp; Jorge Wong; Alexis Lennart; Amanda A Pollard; Pierre N Floriano; Nicolaos Christodoulides; Glennon W Simmons; Yanjie Zhou; Mehnaaz F Ali; John T McDevitt
Journal:  Small       Date:  2011-02-02       Impact factor: 13.281

2.  GNP-CeO2- polyaniline hybrid hydrogel for electrochemical detection of peroxynitrite anion and its integration in a microfluidic platform.

Authors:  Vijayesh Kumar; Ishita Matai; Ankit Kumar; Abhay Sachdev
Journal:  Mikrochim Acta       Date:  2021-11-27       Impact factor: 5.833

3.  Platinized agarose microspheres as a new modifier in graphite paste electrodes for the electrochemical determination of 4-aminophenol.

Authors:  M Tohidinia; A Biabangard; M Noroozifar
Journal:  RSC Adv       Date:  2020-01-16       Impact factor: 4.036

Review 4.  Performance and comparability of laboratory methods for measuring ferritin concentrations in human serum or plasma: A systematic review and meta-analysis.

Authors:  Maria N Garcia-Casal; Juan P Peña-Rosas; Eloisa Urrechaga; Jesus F Escanero; Junsheng Huo; Ricardo X Martinez; Lucero Lopez-Perez
Journal:  PLoS One       Date:  2018-05-03       Impact factor: 3.240

Review 5.  Advancements in Hydrogel-Functionalized Immunosensing Platforms.

Authors:  Suchi Mercy George; Saloni Tandon; Balasubramanian Kandasubramanian
Journal:  ACS Omega       Date:  2020-01-29

6.  Microfluidic-Based Electrochemical Immunosensing of Ferritin.

Authors:  Mayank Garg; Martin Gedsted Christensen; Alexander Iles; Amit L Sharma; Suman Singh; Nicole Pamme
Journal:  Biosensors (Basel)       Date:  2020-08-05
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.