Optimization of the circuit configuration of a pulsatile ECLs: an in vivo experimental study.

Choon Hak Lim1, Ho Sung Son, Jung Joo Lee, Yong Hu Fang, Ki Chul Moon, Chi Bum Ahn, Kyung Hyun Kim, Hye Won Lee, Kyung Sun.   

Abstract

An extracorporeal life support system (ECLS) with a conventional membrane oxygenator requires a driving force for the blood to pass through hollow fiber membranes. We hypothesized that if a gravity-flow hollow fiber membrane oxygenator is installed in the circuit, the twin blood sacs of a pulsatile ECLS (the Twin-Pulse Life Support, T-PLS) can be placed downstream of the membrane oxygenator. This would increase pump output by doubling pulse rate at a given pumpsetting rate while maintaining effective pulsatility. The purpose of this study was to determine the optimal circuit configuration for T-PLS with respect to energy and pump output. Animals were randomly assigned to 2 groups in a total cardiopulmonary bypass model. In the serial group, a conventional membrane oxygenator was located between the twin blood sacs of the T-PLS. In the parallel group, the twin blood sacs were placed downstream of the gravity-flow membrane oxygenator. Energy equivalent pressure (EEP), surplus hemodynamic energy (SHE) and pump output were collected at the different pump-setting rates of 30, 40, and 50 beats per minute (BPM). At a given pump-setting rate the pulse rate doubled in the parallel group. Percent changes of mean arterial pressure to EEP were 13.0 +/- 1.7, 12.0 +/- 1.9, and 7.6 +/- 0.9% in the parallel group, while 22.5 +/- 2.4, 23.2 +/- 1.9, and 21.8 +/- 1.4 in the serial group at 30, 40, and 50 BPM of pump-setting rates. SHE at each pump setting rate was 20,131 +/- 1408, 21,739 +/- 2470, and 15,048 +/- 2108 erg/ cm3 in the parallel group, while 33,968 +/- 3001, 38,232 +/- 3281, 37,964 +/- 2693 erg/cm3 in the serial group. Pump output was higher in the parallel circuit at 40, and 50 BPM pump-setting rates (3.1 +/- 0.2, 3.7 +/- 0.2 L/min vs. 2.2 +/- 0.1 and 2.5 +/- 0.1 L/min, respectively, p =0.01). Either parallel or serial circuit configuration of T-PLS generates effective pulsatility. As for the pump out, the parallel circuit configuration provides higher flow than the serial circuit configuration by doubling the pulse rate at a given pump-setting rate.

Mesh:

Year:  2005        PMID: 16322726     DOI: 10.1097/01.mat.0000177779.59381.95

Source DB:  PubMed          Journal:  ASAIO J        ISSN: 1058-2916            Impact factor:   2.872


  3 in total

1.  International conference on pediatric mechanical circulatory support systems and pediatric cardiopulmonary perfusion: outcomes and future directions.

Authors:  Akif Undar
Journal:  ASAIO J       Date:  2008 Mar-Apr       Impact factor: 2.872

2.  Fulminant myocarditis managed with pulsatile extracorporeal life support; use of Twin Pulse Life support (T-PLS®).

Authors:  Eun Jeung Cho; Joonhwa Hong; Hyun Kang; Ju Won Choe; Sang-Wook Kim
Journal:  J Cardiothorac Surg       Date:  2011-11-24       Impact factor: 1.637

3.  Notice of Retraction.

Authors: 
Journal:  Korean J Thorac Cardiovasc Surg       Date:  2017-10-05
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.