Literature DB >> 16316183

A comprehensive two-dimensional retention time alignment algorithm to enhance chemometric analysis of comprehensive two-dimensional separation data.

Karisa M Pierce1, Lianna F Wood, Bob W Wright, Robert E Synovec.   

Abstract

A comprehensive two-dimensional (2D) retention time alignment algorithm was developed using a novel indexing scheme. The algorithm is termed comprehensive because it functions to correct the entire chromatogram in both dimensions and it preserves the separation information in both dimensions. Although the algorithm is demonstrated by correcting comprehensive two-dimensional gas chromatography (GC x GC) data, the algorithm is designed to correct shifting in all forms of 2D separations, such as LC x LC, LC x CE, CE x CE, and LC x GC. This 2D alignment algorithm was applied to three different data sets composed of replicate GC x GC separations of (1) three 22-component control mixtures, (2) three gasoline samples, and (3) three diesel samples. The three data sets were collected using slightly different temperature or pressure programs to engender significant retention time shifting in the raw data and then demonstrate subsequent corrections of that shifting upon comprehensive 2D alignment of the data sets. Thirty 12-min GC x GC separations from three 22-component control mixtures were used to evaluate the 2D alignment performance (10 runs/mixture). The average standard deviation of first column retention time improved 5-fold from 0.020 min (before alignment) to 0.004 min (after alignment). Concurrently, the average standard deviation of second column retention time improved 4-fold from 3.5 ms (before alignment) to 0.8 ms (after alignment). Alignment of the 30 control mixture chromatograms took 20 min. The quantitative integrity of the GC x GC data following 2D alignment was also investigated. The mean integrated signal was determined for all components in the three 22-component mixtures for all 30 replicates. The average percent difference in the integrated signal for each component before and after alignment was 2.6%. Singular value decomposition (SVD) was applied to the 22-component control mixture data before and after alignment to show the restoration of trilinearity to the data, since trilinearity benefits chemometric analysis. By applying comprehensive 2D retention time alignment to all three data sets (control mixtures, gasoline samples, and diesel samples), classification by principal component analysis (PCA) substantially improved, resulting in 100% accurate scores clustering.

Entities:  

Year:  2005        PMID: 16316183     DOI: 10.1021/ac0511142

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  23 in total

1.  Comprehensive two-dimensional gas chromatography/time-of-flight mass spectrometry peak sorting algorithm.

Authors:  Cheolhwan Oh; Xiaodong Huang; Fred E Regnier; Charles Buck; Xiang Zhang
Journal:  J Chromatogr A       Date:  2007-12-03       Impact factor: 4.759

Review 2.  Fast, comprehensive two-dimensional liquid chromatography.

Authors:  Dwight R Stoll; Xiaoping Li; Xiaoli Wang; Peter W Carr; Sarah E G Porter; Sarah C Rutan
Journal:  J Chromatogr A       Date:  2007-08-30       Impact factor: 4.759

Review 3.  Accurate mass measurements in proteomics.

Authors:  Tao Liu; Mikhail E Belov; Navdeep Jaitly; Wei-Jun Qian; Richard D Smith
Journal:  Chem Rev       Date:  2007-07-25       Impact factor: 60.622

4.  LC-MS Based Detection of Differential Protein Expression.

Authors:  Leepika Tuli; Habtom W Ressom
Journal:  J Proteomics Bioinform       Date:  2009-10-02

5.  DISCO: distance and spectrum correlation optimization alignment for two-dimensional gas chromatography time-of-flight mass spectrometry-based metabolomics.

Authors:  Bing Wang; Aiqin Fang; John Heim; Bogdan Bogdanov; Scott Pugh; Mark Libardoni; Xiang Zhang
Journal:  Anal Chem       Date:  2010-06-15       Impact factor: 6.986

6.  An optimal peak alignment for comprehensive two-dimensional gas chromatography mass spectrometry using mixture similarity measure.

Authors:  Seongho Kim; Aiqin Fang; Bing Wang; Jaesik Jeong; Xiang Zhang
Journal:  Bioinformatics       Date:  2011-04-14       Impact factor: 6.937

7.  A NEW METHOD OF PEAK DETECTION FOR ANALYSIS OF COMPREHENSIVE TWO-DIMENSIONAL GAS CHROMATOGRAPHY MASS SPECTROMETRY DATA.

Authors:  Seongho Kim; Ming Ouyang; Jaesik Jeong; Changyu Shen; Xiang Zhang
Journal:  Ann Appl Stat       Date:  2014-06       Impact factor: 2.083

8.  Semi-automated alignment and quantification of peaks using parallel factor analysis for comprehensive two-dimensional liquid chromatography-diode array detector data sets.

Authors:  Robert C Allen; Sarah C Rutan
Journal:  Anal Chim Acta       Date:  2012-02-19       Impact factor: 6.558

9.  MetPP: a computational platform for comprehensive two-dimensional gas chromatography time-of-flight mass spectrometry-based metabolomics.

Authors:  Xiaoli Wei; Xue Shi; Imhoi Koo; Seongho Kim; Robin H Schmidt; Gavin E Arteel; Walter H Watson; Craig McClain; Xiang Zhang
Journal:  Bioinformatics       Date:  2013-05-11       Impact factor: 6.937

10.  Global peak alignment for comprehensive two-dimensional gas chromatography mass spectrometry using point matching algorithms.

Authors:  Beichuan Deng; Seongho Kim; Hengguang Li; Elisabeth Heath; Xiang Zhang
Journal:  J Bioinform Comput Biol       Date:  2016-09-09       Impact factor: 1.122

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.