Literature DB >> 16316155

Pyrosequencing in a microfluidic flow-through device.

Aman Russom1, Nigel Tooke, Helene Andersson, Göran Stemme.   

Abstract

To explore genome variation meaningfully, there is a critical need for a high-throughput and inexpensive platform for DNA analysis. Pyrosequencing is a nonelectrophoretic bioluminometric DNA sequencing method that uses a four-enzyme mixture reaction to monitor nucleotide incorporation in real time. Currently, the commercialized pyrosequencing technique is limited to a 96-microtiter plate format. However, high throughput and inexpensive pyrosequencing is required to meet the need of screening large numbers of samples. We present here DNA pyrosequencing on a nanoliter-volume microfluidic platform. The microfluidic approach involves the trapping of the DNA on microbeads in an on-chip filter chamber and flow-through of the pyrosequencing reagents to monitor the reaction in real time. Two single-nucleotide polymorphisms were successfully scored to evaluate the microfluidic platform. In addition to significantly reducing reagent costs, microfluidic systems promise to improve the read length by eliminating intermediate product accumulation by constant removal of unincorporated nucleotides and elimination of dilution effects at each reaction cycle in the current plate format. Although only one filter chamber was used in this study, the platform should be readily adaptable to parallel analyses of nanoliter samples using filter chamber arrays to obtain high-throughput DNA analysis.

Mesh:

Substances:

Year:  2005        PMID: 16316155     DOI: 10.1021/ac0507542

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  4 in total

1.  Droplet-based pyrosequencing using digital microfluidics.

Authors:  Deborah J Boles; Jonathan L Benton; Germaine J Siew; Miriam H Levy; Prasanna K Thwar; Melissa A Sandahl; Jeremy L Rouse; Lisa C Perkins; Arjun P Sudarsan; Roxana Jalili; Vamsee K Pamula; Vijay Srinivasan; Richard B Fair; Peter B Griffin; Allen E Eckhardt; Michael G Pollack
Journal:  Anal Chem       Date:  2011-10-14       Impact factor: 6.986

2.  Direct amplification of single-stranded DNA for pyrosequencing using linear-after-the-exponential (LATE)-PCR.

Authors:  Jesse J Salk; J Aquiles Sanchez; Kenneth E Pierce; John E Rice; Kevin C Soares; Lawrence J Wangh
Journal:  Anal Biochem       Date:  2006-02-28       Impact factor: 3.365

3.  Picoliter DNA sequencing chemistry on an electrowetting-based digital microfluidic platform.

Authors:  Erin R Ferguson Welch; Yan-You Lin; Andrew Madison; Richard B Fair
Journal:  Biotechnol J       Date:  2010-12-17       Impact factor: 4.677

4.  Chemical gradient-mediated melting curve analysis for genotyping of SNPs.

Authors:  Aman Russom; Daniel Irimia; Mehmet Toner
Journal:  Electrophoresis       Date:  2009-07       Impact factor: 3.535

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.