Literature DB >> 16314715

Treatment of unstable peritrochanteric femoral fractures using a 95 degrees angled blade plate.

Myung-Chul Yoo1, Yoon-Je Cho, Kang-Il Kim, Mohamad Khairuddin, Young-Soo Chun.   

Abstract

OBJECTIVE: To clarify the efficacy of a 95-degree angled blade plate fixation in the treatment of unstable peritrochanteric fractures of the femur.
DESIGN: Retrospective, clinical study.
SETTING: University hospital. PATIENTS: Thirty-nine consecutive patients with peritrochanteric femoral fractures were followed for a minimum of 12 months. There were 29 subtrochanteric fractures and 10 intertrochanteric fractures (reverse obliquity pattern) for which the compression hip screw could not be used because of comminution of the trochanteric area and fracture extension to the lateral cortex. The mean age of the patient population at the time of operation was 54 (range, 17-71) years. INTERVENTION: Open reduction and internal fixation of the pertrochanteric fractures using a 95 degrees angled blade plate. MAIN OUTCOME MEASUREMENTS: Time to fracture union, operation time, and complications.
RESULTS: Duration of clinical follow-up averaged 26 (range, 12-36) months. The average time to osseous union for those fractures that healed primarily was 19 (range, 13-28) weeks. Two of 39 fractures united with 10 degrees varus deformity, but no corrective surgery was warranted. Limb length discrepancy more than 1.5 cm did not occur. Implant failure before solid bony union occurred in 1 case with a severely comminuted subtrochanteric fracture. Postoperative infection or osteonecrosis of the femoral head did not occur any time throughout the follow-up period.
CONCLUSION: A 95 angled blade plate can be a useful alternative fixation device for the treatment of unstable peritrochanteric femoral fractures.

Entities:  

Mesh:

Year:  2005        PMID: 16314715     DOI: 10.1097/01.bot.0000184141.52330.5e

Source DB:  PubMed          Journal:  J Orthop Trauma        ISSN: 0890-5339            Impact factor:   2.512


  5 in total

1.  [The use of blade plate and dynamic screw plate osteosynthesis].

Authors:  H J Oestern; A Gänsslen
Journal:  Orthopade       Date:  2010-02       Impact factor: 1.087

2.  Functional and Radiological Outcomes of Unstable Proximal Femur Fractures Fixed With Anatomical Proximal Locking Compression Plate.

Authors:  Vamsee Krishna; Aakaash Venkatesan; Ayush Kumar Singh
Journal:  Cureus       Date:  2022-05-11

3.  Surgical Outcomes of Biologic Fixation for Subtrochanteric Fracture Using Locking Compression Plates.

Authors:  Jae Hoon Jang; Jae Min Ahn; Hee Jin Lee; Nam Hoon Moon
Journal:  Hip Pelvis       Date:  2017-03-06

4.  The utility of the angled blade plate in hip fracture nonunion treatment: A report of three cases and review of the literature.

Authors:  Joshua M Lawrenz; Danielle C Marshall; Brendan M Patterson
Journal:  OTA Int       Date:  2019-08-02

5.  Comparison of proximal femoral nail antirotation (PFNA) with AO dynamic condylar screws (DCS) for the treatment for unstable peritrochanteric femoral fractures.

Authors:  Emrah Kemal Sahin; Ahmet Imerci; Hakan Kınık; Levent Karapınar; Umut Canbek; Ahmet Savran
Journal:  Eur J Orthop Surg Traumatol       Date:  2013-02-27
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.