Noninvasive measurement of blood pressure variability: accuracy of the Finometer monitor and comparison with the Finapres device.

R Maestri1, G D Pinna, E Robbi, S Capomolla, M T La Rovere.   

Abstract

To assess the accuracy of spectral indices of arterial pressure variability and baroreflex sensitivity obtained from beat-by-beat noninvasive blood pressure recordings by the Finometer device, we compared these measures with those obtained from intra-arterial recordings. The performance of the Finometer was also compared to the traditional Finapres device. In 19 cardiac disease patients, including myocardial infarction, heart failure and cardiac transplant, we estimated the power of systolic and diastolic pressures in the VLF (0.01-0.04 Hz), LF (0.04-0.15 Hz) and HF (0.15-0.45 Hz) bands and computed absolute and percentage errors relative to intra-arterial brachial pressure. We also computed the characteristic frequency of each band (i.e. the barycentric frequency of spectral components identified in the band). The variability of systolic pressure in the VLF and LF bands was markedly overestimated by both the Finometer and Finapres (p < 0.01), with percentage median errors of respectively 130% and 103% (Finometer), and 134% and 78% (Finapres). The HF power was substantially unchanged using the Finometer and reduced using the Finapres (-28%, p < 0.05). The limits of agreement between noninvasive and invasive spectral measurements were wide. Linear system analysis showed that most (>80%) of the power of noninvasive signals was linearly related to the power of the invasive signal. The characteristic frequency of each band was substantially preserved in both noninvasive signals. The results for diastolic pressure were similar, but the Finapres errors in the VLF and LF bands were lower. Baroreflex sensitivity was significantly underestimated by both devices (Finometer: -31%, Finapres: -24%). Despite previous studies having shown that brachial artery waveform reconstruction performed by the Finometer has improved the accuracy of blood pressure measurement compared to the Finapres device, measurement of blood pressure variability in cardiac disease patients provides worse results in most spectral parameters and a better accuracy only in the HF band of systolic pressure.

Entities:  

Mesh:

Year:  2005        PMID: 16311459     DOI: 10.1088/0967-3334/26/6/021

Source DB:  PubMed          Journal:  Physiol Meas        ISSN: 0967-3334            Impact factor:   2.833


  10 in total

1.  Autonomic dysfunction in children with sleep disordered breathing.

Authors:  Lisa M Walter; Gillian M Nixon; Margot J Davey; Vicki Anderson; Adrian M Walker; Rosemary S C Horne
Journal:  Sleep Breath       Date:  2012-06-09       Impact factor: 2.816

2.  Analysis of beat-to-beat blood pressure variability response to the cold pressor test in the offspring of hypertensive and normotensive parents.

Authors:  Dan Wu; Lin Xu; Derek Abbott; William Kongto Hau; Lijie Ren; Heye Zhang; Kelvin K L Wong
Journal:  Hypertens Res       Date:  2017-02-09       Impact factor: 3.872

3.  Sex differences in autonomic function following maximal exercise.

Authors:  Rebecca M Kappus; Sushant M Ranadive; Huimin Yan; Abbi D Lane-Cordova; Marc D Cook; Peng Sun; I Shevon Harvey; Kenneth R Wilund; Jeffrey A Woods; Bo Fernhall
Journal:  Biol Sex Differ       Date:  2015-12-01       Impact factor: 5.027

4.  A Preliminary Study of the Effectiveness of an Allostatic, Closed-Loop, Acoustic Stimulation Neurotechnology in the Treatment of Athletes with Persisting Post-concussion Symptoms.

Authors:  Charles H Tegeler; Catherine L Tegeler; Jared F Cook; Sung W Lee; Lee Gerdes; Hossam A Shaltout; Christopher M Miles; Sean L Simpson
Journal:  Sports Med Open       Date:  2016-09-14

5.  Cerebral blood volume and oxygen supply uniformly increase following various intrathoracic pressure strains.

Authors:  Zhongxing Zhang; Nina Bolz; Marco Laures; Margit Oremek; Christoph Schmidt; Ming Qi; Ramin Khatami
Journal:  Sci Rep       Date:  2017-08-21       Impact factor: 4.379

6.  Aerobic exercise training in older men and women-Cerebrovascular responses to submaximal exercise: Results from the Brain in Motion study.

Authors:  Sonja L Lake; Veronica Guadagni; Karen D Kendall; Michaela Chadder; Todd J Anderson; Richard Leigh; Jean M Rawling; David B Hogan; Michael D Hill; Marc J Poulin
Journal:  Physiol Rep       Date:  2022-02

7.  Feasibility of Diagnosing Initial Orthostatic Hypotension Using a Continuous Blood Pressure Device in Geriatric Rehabilitation Inpatients: RESORT.

Authors:  Jennifer Tran; Arjen Mol; Rebecca K Iseli; Wen Kwang Lim; Carel G M Meskers; Andrea B Maier
Journal:  Gerontology       Date:  2022-01-17       Impact factor: 5.597

8.  Exploring haemodynamics of haemodialysis using extrema points analysis model.

Authors:  Mohamed Tarek Eldehni; Aghogho Odudu; Christopher William McIntyre
Journal:  Theor Biol Med Model       Date:  2013-05-16       Impact factor: 2.432

9.  Use of an allostatic neurotechnology by adolescents with postural orthostatic tachycardia syndrome (POTS) is associated with improvements in heart rate variability and changes in temporal lobe electrical activity.

Authors:  John E Fortunato; Catherine L Tegeler; Lee Gerdes; Sung W Lee; Nicholas M Pajewski; Meghan E Franco; Jared F Cook; Hossam A Shaltout; Charles H Tegeler
Journal:  Exp Brain Res       Date:  2015-12-08       Impact factor: 1.972

10.  Non-invasive continuous blood pressure measurement based on mean impact value method, BP neural network, and genetic algorithm.

Authors:  Xia Tan; Zhong Ji; Yadan Zhang
Journal:  Technol Health Care       Date:  2018       Impact factor: 1.285