Literature DB >> 16310516

Stability of blood cell counts, hematologic parameters and reticulocytes indexes on the Advia A120 hematologic analyzer.

Giuseppe Lippi1, Gian Luca Salvagno, Gian Pietro Solero, Massimo Franchini, Gian Cesare Guidi.   

Abstract

Delayed sample analysis is not a rare circumstance in clinical and laboratory practice, especially when blood samples are shipped to distant centralized laboratories, when the analysis can not be readily performed, or when retesting is appropriate. In this study we sought to evaluate the stability of conventional and new hematologic parameters in blood specimens stored for as long as 24 hours at 4 degrees C. Of the 21 hematologic parameters tested with the use of the Advia 120 hematologic analyzer (Bayer Diagnostics), means for paired samples of specimens differed significantly over the 24-hour storage period for hematocrit, main corpuscular volume, percentage of macrocytes, platelet count, main platelet volume, reticulocyte count and percentage, and reticulocyte hemoglobin content (all P < .01). We noted no significant changes in the other parameters tested or in the white blood cell differential. The overall distribution of the immature reticulocytes fractions remained substantially unchanged, though the high staining-intensity fraction showed a considerable shift from the baseline measure. Bland-Altman plots and limits-of-agreement analysis showed mean biases between -4.8% and 37.2% and relative coefficients of variations ranging from 0.4% to 32.7%. The 95% agreement interval in the set of differences was satisfactory and almost within the current analytic-quality specifications for desirable bias. The results of this investigation suggest that, within certain limitations for parameters derived or calculated from cellular volumes, blood specimens stored for as long as 24 hours at 4 degrees C may be suitable for hematologic testing.

Mesh:

Year:  2005        PMID: 16310516     DOI: 10.1016/j.lab.2005.08.004

Source DB:  PubMed          Journal:  J Lab Clin Med        ISSN: 0022-2143


  14 in total

Review 1.  Stability of haematological parameters and its relevance on the athlete's biological passport model.

Authors:  Giovanni Lombardi; Patrizia Lanteri; Alessandra Colombini; Giuseppe Lippi; Giuseppe Banfi
Journal:  Sports Med       Date:  2011-12-01       Impact factor: 11.136

Review 2.  Reticulocytes in sports medicine.

Authors:  Giuseppe Banfi
Journal:  Sports Med       Date:  2008       Impact factor: 11.136

3.  The cost-benefit ratio of screening pregnant women for thrombophilia.

Authors:  Gian Luca Salvagno; Giuseppe Lippi; Massimo Franchini; Giovanni Targher; Martina Montagnana; Massimo Franchi; Gian Cesare Guidi
Journal:  Blood Transfus       Date:  2007-11       Impact factor: 3.443

Review 4.  Factors affecting hemoglobin measurement.

Authors:  Lauren Berkow
Journal:  J Clin Monit Comput       Date:  2013-03-26       Impact factor: 2.502

5.  Physiological and pathological population dynamics of circulating human red blood cells.

Authors:  John M Higgins; L Mahadevan
Journal:  Proc Natl Acad Sci U S A       Date:  2010-11-08       Impact factor: 11.205

Review 6.  Markers of iron status in chronic kidney disease.

Authors:  Adam E Gaweda
Journal:  Hemodial Int       Date:  2017-03-22       Impact factor: 1.812

7.  The effects of coronary artery disease severity on time-dependent changes in platelet activation indices in stored whole blood.

Authors:  Christopher J Boos; Balu Balakrishnan; Gregory Y H Lip
Journal:  J Thromb Thrombolysis       Date:  2007-06-16       Impact factor: 2.300

8.  Stability of hematological analytes during 48 hours storage at three temperatures using Cell-Dyn hematology analyzer.

Authors:  Ozmen Sevda Unalli; Yesim Ozarda
Journal:  J Med Biochem       Date:  2021-06-05       Impact factor: 3.402

9.  Effect of the addition of the antioxidant taurine on the complete blood count of whole blood stored at room temperature and at 4ºC for up to 7 days.

Authors:  Mahmoud Mohammed Sirdah; Abdelnasser Kassem Abushahla; Heba Abd Allah Al-Sarraj
Journal:  Rev Bras Hematol Hemoter       Date:  2013

10.  Comparison of Two Methods for the Determination of the Effects of Ionizing Radiation on Blood Cell Counts in Mice.

Authors:  Ana L Romero-Weaver; Ann R Kennedy
Journal:  Int J Biomed Sci       Date:  2012-03-15
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.