Literature DB >> 16310303

Dentist-time expenditure for two different adhesive all-ceramic systems.

Matthias Wurbs1, James F Simon, Markus Troeltzsch, Thomas Denekas, Manfred Wichmann, Sven Reich.   

Abstract

OBJECTIVES: The purpose of this clinical investigation was to compare a chair-side adhesive all-ceramic system to a laboratory processed adhesive all-ceramic system with respect to quality and time expenditure for the dentist.
METHODS: The same dentist treated 10 patients, who were each to receive two large posterior single tooth restorations of similar location and extent. One restoration was made in the laboratory by using the IPS Empress system [LAB], the other one was done chair-side by utilizing the Cerec system [CHAIR]. The time expenditure was measured for [LAB] and [CHAIR] and compared by the Wilcoxon signed rank test. The restorations were also evaluated according to the USPHS criteria.
RESULTS: The mean time expenditure for the dentist with low-level assistance was 111:03 min [S.D.+/-24:09 min] for [LAB] and 115:31 min [S.D.+/-15:54 min] for [CHAIR]. Time expenditure with medium level assistance for the operator was 100:53 min [S.D.+/-23:59] for [LAB] and 105:50 [S.D.+/-15:28] for [CHAIR]. Assuming a high level of assistance, the mean time values were 53:11 min [S.D.+/-14:29] for [LAB] and 54:29 min [S.D.+/-09:21] for [CHAIR]. The baseline investigation according to the modified USPHS criteria did not reveal any differences between [CHAIR] and [LAB].
CONCLUSION: There were no statistical significant differences with respect to time expenditure or quality between [LAB] and [CHAIR] in this study.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16310303     DOI: 10.1016/j.jdent.2005.09.005

Source DB:  PubMed          Journal:  J Dent        ISSN: 0300-5712            Impact factor:   4.379


  4 in total

1.  Seven-year clinical performance of CEREC-2 all-ceramic CAD/CAM restorations placed within deeply destroyed teeth.

Authors:  Matthias J Roggendorf; Bianka Kunzi; Johannes Ebert; Hubert C Roggendorf; Roland Frankenberger; Sven M Reich
Journal:  Clin Oral Investig       Date:  2011-12-07       Impact factor: 3.573

2.  Efficiency of a mathematical model in generating CAD/CAM-partial crowns with natural tooth morphology.

Authors:  Andreas Ender; Werner H Mörmann; Albert Mehl
Journal:  Clin Oral Investig       Date:  2010-02-09       Impact factor: 3.573

3.  Accuracy of Conventional and Digital Methods of Obtaining Full-Arch Dental Impression (In Vitro Study).

Authors:  Hassan A Husein; Mhd Luai Morad; Shaza Kanout
Journal:  Cureus       Date:  2022-09-11

4.  Comparison and evaluation of the morphology of crowns generated by biogeneric design technique with CEREC chairside system.

Authors:  Fang Wang; Qingqing Tang; Shuang Xi; Ruirui Liu; Lin Niu
Journal:  PLoS One       Date:  2020-01-16       Impact factor: 3.240

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.