Literature DB >> 16309364

Protein biochip systems for the clinical laboratory.

Anne Marie Dupuy1, Sylvain Lehmann, Jean Paul Cristol.   

Abstract

Classical methods of protein analysis such as electrophoresis, ELISA and liquid chromatography are generally time-consuming, labor-intensive and lack high-throughput capacity. In addition, all existing methods used to measure proteins necessitate multiple division of the original sample and individual tests carried out for each substance, with an associated cost for each test. The chip system allows several tests to be performed simultaneously without dividing the original patient sample. This system facilitates the development of multiplexed assays that simultaneously measure many different analytes in a small sample volume. These emerging technologies fall into two categories: 1) spotted array-based tools, and 2) microfluidic-based tools. Miniaturized and multiplexed immunoassays allow a great deal of information to be obtained from a single sample. These analytical systems are referred to as "lab-on-a-chip" devices. This article presents current trends and advances in miniaturized multiplexed immunoassay technologies, reviewing different systems from research to point-of-care assays. We focus on a subset of chip-based assays that may be used in a clinical laboratory and are directly applicable for biomedical diagnosis. Recent advances in biochip assays combine the power of miniaturization, microfluidics, micro- to nanoparticles, and quantification. A number of applications are just beginning to be explored. The power of biochip assays offers great promise for point-of-care clinical testing and monitoring of many important analytes.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16309364     DOI: 10.1515/CCLM.2005.223

Source DB:  PubMed          Journal:  Clin Chem Lab Med        ISSN: 1434-6621            Impact factor:   3.694


  18 in total

Review 1.  Invited Review Article: Review of centrifugal microfluidic and bio-optical disks.

Authors:  David D Nolte
Journal:  Rev Sci Instrum       Date:  2009-10       Impact factor: 1.523

2.  Immunonutrition before and during radiochemotherapy: improvement of inflammatory parameters in head and neck cancer patients.

Authors:  Christelle Machon; Simon Thezenas; Anne-Marie Dupuy; Eric Assenat; Françoise Michel; Emilie Mas; Pierre Senesse; Jean-Paul Cristol
Journal:  Support Care Cancer       Date:  2012-03-28       Impact factor: 3.603

3.  Particles and microfluidics merged: perspectives of highly sensitive diagnostic detection.

Authors:  Tania Konry; Shyam Sundhar Bale; Abhinav Bhushan; Keyue Shen; Erkin Seker; Boris Polyak; Martin Yarmush
Journal:  Mikrochim Acta       Date:  2012-02       Impact factor: 5.833

4.  Evaluation of specific fecal protein biochips for the diagnosis of colorectal cancer.

Authors:  Hui-Peng Wang; Yang-Yun Wang; Jie Pan; Rong Cen; Yuan-Kun Cai
Journal:  World J Gastroenterol       Date:  2014-02-07       Impact factor: 5.742

5.  Microfluidic chip for fast bioassays-evaluation of binding parameters.

Authors:  Jakub Stepánek; Michal Pribyl; Dalimil Snita; Milos Marek
Journal:  Biomicrofluidics       Date:  2007-04-25       Impact factor: 2.800

6.  Fine-tuning of the prediction of mortality in hemodialysis patients by use of cytokine proteomic determination.

Authors:  Stéphanie Badiou; Jean-Paul Cristol; Isabelle Jaussent; Nathalie Terrier; Marion Morena; François Maurice; Hélène Leray-Moragues; Jean-Pierre Rivory; Lofti Chalabi; Cécile Delcourt; Bernard Canaud; Anne-Marie Dupuy
Journal:  Clin J Am Soc Nephrol       Date:  2008-01-30       Impact factor: 8.237

7.  Protein biochip array technology to monitor rituximab in rheumatoid arthritis.

Authors:  S Fabre; C Guisset; L Tatem; N Dossat; A M Dupuy; J D Cohen; J P Cristol; J P Daures; C Jorgensen
Journal:  Clin Exp Immunol       Date:  2009-03       Impact factor: 4.330

8.  Protein biochip array technology for cytokine profiling predicts etanercept responsiveness in rheumatoid arthritis.

Authors:  S Fabre; A M Dupuy; N Dossat; C Guisset; J D Cohen; J P Cristol; J P Daures; C Jorgensen
Journal:  Clin Exp Immunol       Date:  2008-06-18       Impact factor: 4.330

9.  Programmable bio-nano-chip system: a flexible point-of-care platform for bioscience and clinical measurements.

Authors:  Michael P McRae; Glennon W Simmons; Jorge Wong; Basil Shadfan; Sanjiv Gopalkrishnan; Nicolaos Christodoulides; John T McDevitt
Journal:  Lab Chip       Date:  2015-08-26       Impact factor: 6.799

10.  Catch and release: integrated system for multiplexed detection of bacteria.

Authors:  Jasenka Verbarg; William D Plath; Lisa C Shriver-Lake; Peter B Howell; Jeffrey S Erickson; Joel P Golden; Frances S Ligler
Journal:  Anal Chem       Date:  2013-04-30       Impact factor: 6.986

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.