Literature DB >> 16308895

Ion motion in the rectangular wave quadrupole field and digital operation mode of a quadrupole ion trap mass spectrometer.

L Ding1, S Kumashiro.   

Abstract

A quadrupolar electric field driven by a rectangular wave voltage can be used for mass-selective storage and analysis. The ion motion in such an electric field is derived, and the stability of ions is presented in the a-q diagram that is commonly used for sinusoidal wave quadrupole mass spectrometry in association with the solution of the Mathieu equation. The pseudo-potential well is discussed in an approximation that leads to the relation of secular frequency to operating parameters. A scheme for a digital ion trap mass spectrometer is described, based on this theory. An ion optics simulation was performed to check the theory of resonant ejection, and to prove the feasibility of the mass scan method for a practical ion trap of such geometry. (c) 2005 John Wiley & Sons, Ltd

Year:  2006        PMID: 16308895     DOI: 10.1002/rcm.2253

Source DB:  PubMed          Journal:  Rapid Commun Mass Spectrom        ISSN: 0951-4198            Impact factor:   2.419


  6 in total

1.  Matrix methods for the calculation of stability diagrams in quadrupole mass spectrometry.

Authors:  N V Konenkov; M Sudakov; D J Douglas
Journal:  J Am Soc Mass Spectrom       Date:  2002-06       Impact factor: 3.109

2.  Digital asymmetric waveform isolation (DAWI) in a digital linear ion trap.

Authors:  Francesco L Brancia; Bryan McCullough; Andrew Entwistle; J Günter Grossmann; Li Ding
Journal:  J Am Soc Mass Spectrom       Date:  2010-05-07       Impact factor: 3.109

3.  Mapping the stability diagram of a digital ion trap (DIT) mass spectrometer varying the duty cycle of the trapping rectangular waveform.

Authors:  Alberto Berton; Pietro Traldi; Li Ding; Francesco L Brancia
Journal:  J Am Soc Mass Spectrom       Date:  2008-01-31       Impact factor: 3.109

4.  Using Digital Waveforms to Mitigate Solvent Clustering During Mass Filter Analysis of Proteins.

Authors:  Bojana Opačić; Nathan M Hoffman; Zachary P Gotlib; Brian H Clowers; Peter T A Reilly
Journal:  J Am Soc Mass Spectrom       Date:  2018-07-09       Impact factor: 3.109

5.  Resonance activation and collision-induced-dissociation of ions using rectangular wave dipolar potentials in a digital ion trap mass spectrometer.

Authors:  Fuxing Xu; Liang Wang; Xinhua Dai; Xiang Fang; Chuan-Fan Ding
Journal:  J Am Soc Mass Spectrom       Date:  2014-01-22       Impact factor: 3.109

6.  Characteristics of Ion Activation and Collision Induced Dissociation Using Digital Ion Trap Technology.

Authors:  Fuxing Xu; Qiankun Dang; Xinhua Dai; Xiang Fang; Yuanyuan Wang; Li Ding; Chuan-Fan Ding
Journal:  J Am Soc Mass Spectrom       Date:  2016-05-05       Impact factor: 3.109

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.