Literature DB >> 16308002

Cerebral microembolization during off-pump coronary artery bypass surgery with the Symmetry aortic connector device.

Mona Skjelland1, Jacob Bergsland, Runar Lundblad, Per Snorre Lingaas, Kjell Arne Rein, Steinar Halvorsen, Jan L Svennevig, Erik Fosse, Rainer Brucher, David Russell.   

Abstract

OBJECTIVE: The use of aortic connector systems for proximal vein grafts in off-pump coronary artery bypass grafting might minimize aortic manipulation by eliminating the need for partial aortic clamping. The objective of this study was to asses whether use of a Symmetry connector (St Jude Medical, Inc, St Paul, Minn) reduced intraoperative cerebral embolization.
METHODS: Thirty-two consecutive patients underwent off-pump coronary artery bypass grafting. Sixteen patients received at least one mechanical proximal vein graft anastomosis with a Symmetry aortic connector system. Sixteen patients representing the control group underwent operations with standard suturing techniques using partial aortic clamping. During surgical intervention, all patients were monitored continuously with multifrequency transcranial Doppler scanning, which detected and differentiated cerebral emboli.
RESULTS: There were significantly more cerebral emboli in the Symmetry group (median, 36) compared with the control group (median, 11; P = .027). This was due to a higher number of gaseous emboli in the Symmetry group than in the control group (median, 27 vs 8; P = .014), whereas there was no significant difference regarding the number of solid emboli (median, 7 vs 3; P = .139).
CONCLUSION: Use of a Symmetry connector system during proximal vein graft anastomosis increased the number of emboli to the brain compared with a standard technique in coronary bypass surgery without cardiopulmonary bypass.

Entities:  

Mesh:

Year:  2005        PMID: 16308002     DOI: 10.1016/j.jtcvs.2005.08.015

Source DB:  PubMed          Journal:  J Thorac Cardiovasc Surg        ISSN: 0022-5223            Impact factor:   5.209


  4 in total

1.  Incidence of Cerebral Microemboli in Single-Dose vs. Multidose Cardioplegia in Adult Cardiac Surgery.

Authors:  Laith Mukdad; William Toppen; Yas Sanaiha; Aditya Mantha; Stephanie Bland; Richard Shemin; Peyman Benharash
Journal:  J Extra Corpor Technol       Date:  2018-09

Review 2.  Cerebrovascular Events After No-Touch Off-Pump Coronary Artery Bypass Grafting, Conventional Side-Clamp Off-Pump Coronary Artery Bypass, and Proximal Anastomotic Devices: A Meta-Analysis.

Authors:  Wojciech Pawliszak; Mariusz Kowalewski; Giuseppe Maria Raffa; Pietro Giorgio Malvindi; Magdalena Ewa Kowalkowska; Krzysztof Aleksander Szwed; Alina Borkowska; Janusz Kowalewski; Lech Anisimowicz
Journal:  J Am Heart Assoc       Date:  2016-02-18       Impact factor: 5.501

3.  Clinical outcomes of automated anastomotic devices: A metanalysis.

Authors:  Linda Renata Micali; Francesco Matteucci; Orlando Parise; Cecilia Tetta; Amalia Ioanna Moula; Monique de Jong; Francesco Londero; Sandro Gelsomino
Journal:  J Card Surg       Date:  2019-08-31       Impact factor: 1.620

4.  Safe introduction and quality control of new methods in coronary surgery.

Authors:  Jacob Bergsland
Journal:  Acta Inform Med       Date:  2011-12