Totally endoscopic robotic-assisted repair of patent ductus arteriosus and vascular ring in children.

Yoshihiro Suematsu1, Bassem N Mora, Tomislav Mihaljevic, Pedro J del Nido.   

Abstract

BACKGROUND: This study reports on our initial experience with robotically assisted patent ductus arteriosus (PDA) closure and vascular ring division in children.
METHODS: From April 2002 to May 2004, 15 patients underwent PDA closure (n = 9) and vascular ring repair (n = 6) by a totally endoscopic approach, utilizing the Da Vinci robotic system. The mean age of the patients was 8.3 +/- 4.7 years (range, 3 to 18) and the mean weight, 35.5 +/- 19.0 kg (range, 14.1 to 77.0 kg). Three thoracoscopic trocars were used to accommodate the endoscopic camera and two surgical instruments with an additional small incision for lung retraction. After dissection by the surgeon seated at the master console, PDA ligation with clips or division of the atretic arch and ductal ligament was performed.
RESULTS: Total operative times were 170 +/- 46 minutes (PDA) and 167 +/- 48 minutes (vascular ring). One patient with vascular ring was converted to thoracotomy because of dense adhesions due to previous surgery. Precise and easy surgical maneuver was possible with the articulated surgical instruments and three-dimensional visualization in 14 patients. Intraoperative transesophageal echocardiography confirmed no persistent shunt in all PDA patients. No laryngeal nerve injury and hemorrhage were noted. All patients were extubated in the operating room. Median length of postoperative hospital stay was 1.5 days.
CONCLUSIONS: Robotically assisted PDA closure and vascular ring division is a feasible and safe procedure. Future technologic improvement, including smaller instrument size and incorporation of tactile feedback, may permit application of this technique to even younger infants and intracardiac repairs.

Entities:  

Mesh:

Year:  2005        PMID: 16305894     DOI: 10.1016/j.athoracsur.2005.05.078

Source DB:  PubMed          Journal:  Ann Thorac Surg        ISSN: 0003-4975            Impact factor:   4.330


  9 in total

1.  Common aortic arch anomalies: diagnosis and management.

Authors:  Amy L Juraszek; Kristine J Guleserian
Journal:  Curr Treat Options Cardiovasc Med       Date:  2006-09

Review 2.  Minimal incision congenital cardiac surgery.

Authors:  Pedro J del Nido
Journal:  Semin Thorac Cardiovasc Surg       Date:  2007

Review 3.  Integrate imaging approach for minimally invasive and robotic procedures.

Authors:  Nikolay A Ivanov; Daniel B Green; T Sloane Guy
Journal:  J Thorac Dis       Date:  2017-04       Impact factor: 2.895

4.  Laparoscopic versus robot-assisted Nissen fundoplication in an infant pig model.

Authors:  Alexandra Krauss; Thomas Neumuth; Robin Wachowiak; Bernd Donaubauer; Werner Korb; Oliver Burgert; Oliver J Muensterer
Journal:  Pediatr Surg Int       Date:  2011-12-27       Impact factor: 1.827

Review 5.  Robotics and imaging in congenital heart surgery.

Authors:  Nikolay V Vasilyev; Pierre E Dupont; Pedro J del Nido
Journal:  Future Cardiol       Date:  2012-03

6.  New technologies for surgery of the congenital cardiac defect.

Authors:  David Kalfa; Emile Bacha
Journal:  Rambam Maimonides Med J       Date:  2013-07-25

Review 7.  Anesthetic Implications of Robotic-Assisted Surgery in Pediatric Patients.

Authors:  Mayuko Wakimoto; Marc Michalsky; Olubukola Nafiu; Joseph Tobias
Journal:  Robot Surg       Date:  2021-05-25

Review 8.  Outcomes in robotic cardiac surgery.

Authors:  Evelio Rodriguez; W Randolph Chitwood
Journal:  J Robot Surg       Date:  2007-01-16

Review 9.  Robot-assisted surgery in children: current status.

Authors:  C K Sinha; M Haddad
Journal:  J Robot Surg       Date:  2008-01-04
  9 in total