Literature DB >> 16303878

Tension-band wiring for fractures of the fifth metatarsal located in the junction of the proximal metaphysis and diaphysis.

Janne Sarimo1, Jussi Rantanen, Sakari Orava, Jouko Alanen.   

Abstract

BACKGROUND: Fractures of the proximal fifth metatarsal, other than those involving the tuberosity, have a tendency to delayed union or even nonunion. HYPOTHESIS: Tension-band wire technique is a good alternative in treating fractures of the fifth metatarsal located in the proximal junction of the metaphysis and the diaphysis. STUDY
DESIGN: Case series; level of evidence, 4.
METHODS: Between 1996 and 2001, a total of 27 cases of proximal metaphysial/diaphysial fractures of the fifth metatarsal were treated with tension-band wiring. All of the patients had undergone prior unsuccessful nonoperative or operative treatment. The mean delay from the diagnosis of the fracture to the final operative procedure was 19.5 weeks (range, 6-48 weeks).
RESULTS: The mean length of follow-up was 35 months (range, 12-70 months). All patients were able to return to their prior levels of activity. The mean time for union as shown on radiographs was 12.8 weeks, and the return to full activity took 8 to 20 weeks (mean, 14.7 weeks). There were no delayed unions, nonunions, or refractures during the follow-up.
CONCLUSION: The tension-band wire technique seems to give good results in the treatment of proximal metaphysial/diaphysial fractures of the fifth metatarsal in cases of primary unsuccessful nonoperative treatment or primary unsuccessful intramedullary screw fixation.

Entities:  

Mesh:

Year:  2005        PMID: 16303878     DOI: 10.1177/0363546505281803

Source DB:  PubMed          Journal:  Am J Sports Med        ISSN: 0363-5465            Impact factor:   6.202


  11 in total

1.  Intramedullary screw fixation of proximal fifth metatarsal fractures in athletes.

Authors:  Marta Maria Teixeira de Oliveira Massada; Manuel Alexandre Negrais Pinho Gonçalves Pereira; Ricardo Jorge Gomes de Sousa; Paulo Guimarães Costa; José Leandro da Rocha Massada
Journal:  Acta Ortop Bras       Date:  2012       Impact factor: 0.513

2.  Fractures in sport: Optimising their management and outcome.

Authors:  Greg Aj Robertson; Alexander M Wood
Journal:  World J Orthop       Date:  2015-12-18

3.  LCP distal ulna hook plate as alternative fixation for fifth metatarsal base fracture.

Authors:  Sang Ki Lee; Ju Sang Park; Won Sik Choy
Journal:  Eur J Orthop Surg Traumatol       Date:  2012-08-22

4.  Surgical results of 5th metatarsal stress fracture using modified tension band wiring.

Authors:  Kyung Tai Lee; Young Uk Park; Ki Won Young; Jin Su Kim; Jun Beom Kim
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-02-03       Impact factor: 4.342

Review 5.  Treatment and return to sport following a Jones fracture of the fifth metatarsal: a systematic review.

Authors:  Andrew J Roche; James D F Calder
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2012-09-06       Impact factor: 4.342

6.  Intramedullary screw fixation with bone autografting to treat proximal fifth metatarsal metaphyseal-diaphyseal fracture in athletes: a case series.

Authors:  Sachiyuki Tsukada; Hiroo Ikeda; Yoshie Seki; Masayuki Shimaya; Akiho Hoshino; Sadao Niga
Journal:  Sports Med Arthrosc Rehabil Ther Technol       Date:  2012-07-20

Review 7.  Fifth metatarsal fractures and current treatment.

Authors:  Julia Bowes; Richard Buckley
Journal:  World J Orthop       Date:  2016-12-18

Review 8.  Proximal Fifth Metatarsal Fractures: Anatomy, Classification, Treatment and Complications.

Authors:  Chi Nok Cheung; Tun Hing Lui
Journal:  Arch Trauma Res       Date:  2016-06-13

9.  Variable Angle Locking Compression Plate as Alternative Fixation for Jones Fractures: A Case Series.

Authors:  Kaylee A Miller; Alexander C M Chong; Timothy P Uglem
Journal:  Kans J Med       Date:  2019-05-15

10.  Peroneus brevis as source of instability in Jones fracture fixation.

Authors:  Madeleine Willegger; Emir Benca; Lena Hirtler; Lukas Moser; Shahin Zandieh; Reinhard Windhager; Reinhard Schuh
Journal:  Int Orthop       Date:  2020-05-05       Impact factor: 3.075

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.