Literature DB >> 16303515

Feasibility of contact lens fitting on keratoconus patients with INTACS inserts.

Richard L Nepomuceno1, Brian S Boxer Wachler, Barry A Weissman.   

Abstract

PURPOSE: To demonstrate the feasibility of contact lens fitting in keratoconus patients with INTACS inserts.
METHODS: A chart review was conducted of all patients with bilateral keratoconus who were treated with INTACS inserts on one eye and who were subsequently referred for contact lens fitting in a university based contact lens practice between April 2000 and April 2002. The study was a retrospective, non-comparative case series. The uncorrected and best spectacle corrected visual acuity (BSCVA) after INTACS implantation surgery, postoperative best contact lens-corrected visual acuity (BCLVA), number of diagnostic contact lenses used, number of contact lenses ordered within a 4-month follow-up period, contact lens complications encountered, final base curves, final lens powers, and final wearing times were determined.
RESULTS: Three keratoconic patients meeting the selection criteria were found through the chart review. Prior to surgery, all patients had uncorrected visual acuity (UCVA) of 2.0 logMAR (counting fingers). This improved to a mean of 0.81+/-0.25 logMAR (20/125-1) after surgery. Mean BSCVA also improved from 0.51+/-0.30 logMAR (20/60-2) to 0.30+/-0.16 logMAR (20/40). The mean postoperative best contact lens-corrected visual acuity was 0.02+/-0.10 logMAR (20/20-1). The number of diagnostic lenses ranged from 1 to 7. The numbers of contact lenses ordered during the 4-month follow up period ranged from 1 to 3. Two eyes were fitted with larger than usual lens designs made of rigid gas-permeable material and one eye was fitted with a toric soft lens. The final lens power ranged from +1.25 to -21.0D with a mean spherical equivalent of -7.46+/-11.89 D. Final wearing times ranged from 2.5 to 12.0h.
CONCLUSION: Fitting contact lenses on keratoconus patients who have INTACS inserts is feasible and has a role in augmenting their vision.

Entities:  

Year:  2003        PMID: 16303515     DOI: 10.1016/S1367-0484(03)00049-3

Source DB:  PubMed          Journal:  Cont Lens Anterior Eye        ISSN: 1367-0484            Impact factor:   3.077


  7 in total

Review 1.  INTACS for keratoconus.

Authors:  Yaron S Rabinowitz
Journal:  Int Ophthalmol Clin       Date:  2006

Review 2.  [Keratoconus lenses: the small correction miracle].

Authors:  U Klühspies; A Grunder; S Goebels; F Schirra; B Seitz
Journal:  Ophthalmologe       Date:  2013-09       Impact factor: 1.059

3.  Intrastromal corneal ring segment implantation in 219 keratoconic eyes at different stages.

Authors:  José F Alfonso; Carlos Lisa; Luis Fernández-Vega; David Madrid-Costa; Robert Montés-Micó
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2011-08-13       Impact factor: 3.117

4.  New surgical approaches to the management of keratoconus and post-LASIK ectasia.

Authors:  Bryan U Tan; Tracy L Purcell; Luis F Torres; David J Schanzlin
Journal:  Trans Am Ophthalmol Soc       Date:  2006

Review 5.  INTACS for keratoconus and ectasia after LASIK.

Authors:  Yaron S Rabinowitz
Journal:  Int Ophthalmol Clin       Date:  2013

6.  Intrastromal corneal ring implants for corneal thinning disorders: an evidence-based analysis.

Authors: 
Journal:  Ont Health Technol Assess Ser       Date:  2009-04-01

7.  Mini-scleral Contact Lens for Management of Poor Visual Outcomes after Intrastromal Corneal Ring Segments Implantation in Keratoconus.

Authors:  Fatemeh Alipour; Firoozeh Rahimi; Mohammad Naser Hashemian; Zahra Ajdarkosh; Ramak Roohipoor; Masoumeh Mohebi
Journal:  J Ophthalmic Vis Res       Date:  2016 Jul-Sep
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.