A novel instrument to quantify the tension of upper and lower eyelids.

K Ehrmann1, I Francis, F Stapleton.   

Abstract

An instrument was developed for the objective measurement of passive lid tension of the upper and lower eyelid. Eyelid tension is defined as the first derivative of the force over elongation function. Lid tension was determined by gripping the eyelid at the eyelashes and displacing the lid while measuring the force exerted by the eyelid. Two motorised spindles provided motion control of the gripper in anterior/posterior and nasal/temporal directions. Each axis was fitted with a sensitive force transducer to record the force while stretching and relaxing the eyelid. Motion control, data collection and data analysis were computer controlled, with various user-selectable options for measurement speed, direction and end-of-measurement conditions. Calibration of the instrument reduced the maximum error of the recorded forces to +/- 10 mN. Repeatability for on-eye measurements was verified by multiple measurements on the same eye under identical conditions. Preliminary results from a pilot study, investigating differences between Asian and Caucasian lid tension showed no statistically significant difference between the two groups.

Year:  2001        PMID: 16303456     DOI: 10.1016/s1367-0484(01)80015-1

Source DB:  PubMed          Journal:  Cont Lens Anterior Eye        ISSN: 1367-0484            Impact factor:   3.077


  4 in total

1.  Relationship Between Eyelid Pressure and Lacrimal Status in Mild Facial Nerve Palsy.

Authors:  Patricia Ann L Lee; Aric Vaidya; Shinjiro Kono; Hirohiko Kakizaki; Yasuhiro Takahashi
Journal:  Cureus       Date:  2021-01-20

2.  Assessment of Eyelid Pressure Using a Novel Pressure Measurement Device in Patients With Moderate-to-Severe Dry Eye Disease.

Authors:  Jingyi Wang; Jiayu Bao; Wenxiu Song; Siyuan Li; Yiran Hao; Lei Tian; Ying Jie
Journal:  Front Med (Lausanne)       Date:  2022-02-07

3.  The changes in corneal astigmatism after botulinum toxin-a injection in patients with blepharospasm.

Authors:  Nam Ju Moon; Hyeon Il Lee; Jae Chan Kim
Journal:  J Korean Med Sci       Date:  2006-02       Impact factor: 2.153

4.  A novel standardized distraction test to evaluate lower eyelid tension using three-dimensional stereophotogrammetry.

Authors:  Xiaoyi Hou; Alexander C Rokohl; Marius M Meinke; Senmao Li; Jinhua Liu; Wanlin Fan; Ming Lin; Renbing Jia; Yongwei Guo; Ludwig M Heindl
Journal:  Quant Imaging Med Surg       Date:  2021-08
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.