Literature DB >> 16303386

Analysis of the repeatability of tear break-up time measurement techniques on asymptomatic subjects before, during and after contact lens wear.

M Elliott1, H Fandrich, T Simpson, D Fonn.   

Abstract

This study assessed the repeatability of various methods of measuring tear break-up time (TBUT) with and without soft contact lenses (CLs). TBUT was measured on 22 subjects with the tearscope, videokeratoscope and slit-lamp before and after 30 min of soft CL wear, and immediately after CL removal. Slit-lamp corneal TBUT was measured with fluorescein and without fluorescein while wearing CLs. TBUT was measured three times on the right eye only, using each technique in randomised order. TBUT measurements on CLs were repeated a second day. TBUT measurements were highly variable under all conditions and our results indicated a lack of correlation between techniques. The videokeratoscope was the least repeatable; while the tearscope was the most repeatable technique.

Entities:  

Year:  1998        PMID: 16303386     DOI: 10.1016/s1367-0484(98)80002-7

Source DB:  PubMed          Journal:  Cont Lens Anterior Eye        ISSN: 1367-0484            Impact factor:   3.077


  6 in total

Review 1.  Tear exchange and contact lenses: a review.

Authors:  Alex Muntz; Lakshman N Subbaraman; Luigina Sorbara; Lyndon Jones
Journal:  J Optom       Date:  2015-01-07

2.  Species variation and spatial differences in mucin expression from corneal epithelial cells.

Authors:  Brian C Leonard; Bernardo Yañez-Soto; Vijay Krishna Raghunathan; Nicholas L Abbott; Christopher J Murphy
Journal:  Exp Eye Res       Date:  2016-09-08       Impact factor: 3.467

3.  Comparative HPLC-MS analysis of canine and human meibomian lipidomes: many similarities, a few differences.

Authors:  Igor A Butovich; Anna M Borowiak; J Corinna Eule
Journal:  Sci Rep       Date:  2011-06-27       Impact factor: 4.379

4.  The Berkeley Dry Eye Flow Chart: A fast, functional screening instrument for contact lens-induced dryness.

Authors:  Andrew D Graham; Erika L Lundgrin; Meng C Lin
Journal:  PLoS One       Date:  2018-01-24       Impact factor: 3.240

5.  Sodium Hyaluronate in the Treatment of Dry Eye Syndrome: A Systematic Review and Meta-Analysis.

Authors:  Bryan Chin Hou Ang; James Jie Sng; Priscilla Xin Hui Wang; Hla Myint Htoon; Louis Hak Tien Tong
Journal:  Sci Rep       Date:  2017-08-21       Impact factor: 4.379

Review 6.  Tear instability importance, mechanisms, validity and reliability of assessment.

Authors:  Charles W Mcmonnies
Journal:  J Optom       Date:  2018-01-11
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.