Literature DB >> 16303031

Review article: oesophageal pH monitoring--technologies, interpretation and correlation with clinical outcomes.

P J Kahrilas1, J E Pandolfino.   

Abstract

Using a simple 'test' to diagnose gastro-oesophageal reflux disease is difficult because accurately measuring gastric refluxate and correlating reflux events with symptom episodes is complex. This paper reviews the safety, tolerability and diagnostic accuracy of Bravo (Medtronic, Shoreview, MN, USA), ambulatory oesophageal pH monitoring technology. Catheter-based pH electrodes inhibit patients' normal activity, and can yield erroneous results because of placement or subsequent migration of the probe or errors in the thermal compensation algorithm that is requisite for antimony pH electrodes. Bravo pH studies reliably discriminated oesophagitis patients from controls, but are less discriminatory in endoscopy-negative gastro-oesophageal reflux disease patients. The Bravo system can be accurately placed using endoscopic landmarks and pH studies demonstrated more accurate in vivo pH recording than with a catheter-based system. The Bravo system detected fewer reflux events of short duration compared with a catheter-based system. Studies examining the correlation between reflux events and symptoms have not yet been conducted using the Bravo system. In conclusion, the Bravo system offers a more user-friendly ambulatory pH monitoring technique that more accurately records pH compared with a catheter-based system. More research is needed to determine whether the detection of reflux events with Bravo will provide a good correlation with symptom episodes.

Entities:  

Mesh:

Year:  2005        PMID: 16303031     DOI: 10.1111/j.1365-2036.2005.02710.x

Source DB:  PubMed          Journal:  Aliment Pharmacol Ther        ISSN: 0269-2813            Impact factor:   8.171


  3 in total

1.  Revenge of the NERDs: Cadherin Fragments Differentiate Functional Heartburn from Non-erosive Reflux Disease.

Authors:  Carlo Calabrese; Marco Salice
Journal:  Dig Dis Sci       Date:  2018-03       Impact factor: 3.199

2.  Inconsistency in the Diagnosis of Functional Heartburn: Usefulness of Prolonged Wireless pH Monitoring in Patients With Proton Pump Inhibitor Refractory Gastroesophageal Reflux Disease.

Authors:  Roberto Penagini; Rami Sweis; Aurelio Mauro; Gerson Domingues; Andres Vales; Daniel Sifrim
Journal:  J Neurogastroenterol Motil       Date:  2015-03-30       Impact factor: 4.924

3.  Reliability, Safety and Effectiveness of the Bravo(TM) Capsule: A Catheter-free pH Monitoring System for Evaluation of Gastroesophageal Reflux Disease in Children.

Authors:  Manoochehr Karjoo; Mirza Beg; Shannon Kesselring
Journal:  Middle East J Dig Dis       Date:  2012-01
  3 in total