Literature DB >> 16302138

[16-row multidetector CT angiography of the aortoiliac system and lower extremity arteries: contrast enhancement and image quality using a standarized examination protocol].

B C Meyer1, C Ribbe, M Kruschewski, K-J Wolf, T Albrecht.   

Abstract

PURPOSE: To assess the degree of enhancement and image quality of 16-slice multidetector CT angiography (MDCTA) of pelvic and lower limb arteries with a monophasic contrast medium injection protocol.
MATERIALS AND METHODS: Fifty patients underwent a CT angiography of the pelvic and lower limb arteries using the following parameters: collimation 16 x 1.5 mm, rotation time 0.5 s, table feed 40 mm/sec, slice thickness 2 mm, reconstruction interval 1.2 mm, 100 ml Iomeprol 400 + 60 ml normal saline, flow rate 4 ml/s, bolus tracking (threshold of 250 DeltaHU in aorta). Arterial enhancement was measured in all arterial segments. Maximum intensity projections (MIP) together with axial images were reviewed by two radiologists (consensus). If the results were inconclusive for stenosis, additional curved multiplanar reformations (MPR) were performed.
RESULTS: The mean arterial enhancement values were aorta: 314 +/- 69, pelvis: 342 +/- 105, thigh: 347 +/- 139, calf: 231 +/- 109 DeltaHU. The image quality was judged as excellent in 346 (77.6 %), adequate in 76 (17 %), and inadequate in 24 (5.4 %, all but one in calf and foot) of 446 arterial territories. An override of the contrast bolus below the knee occurred in 2 patients rendering the calf arteries nondiagnostic. Venous enhancement occurred in 13 patients but this compromised the diagnostic assessment in only one case. Additional MPRs were required accurately to assess stenoses in 22 of 200 arterial levels in 16 patients with marked arterial calcifications.
CONCLUSION: 16-slice MDCTA with a monophasic contrast bolus of Iomeprol 400 provided good arterial enhancement and diagnostic image quality in 94.6 % of the depicted arterial segments. The majority (67 %) of nondiagnostic segments were below the ankle. MPRs were required in patients with marked calcification for accurate assessment of stenosis.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16302138     DOI: 10.1055/s-2005-858486

Source DB:  PubMed          Journal:  Rofo        ISSN: 1438-9010


  4 in total

1.  Quantitative and qualitative evaluation of the influence of different table feeds on visualization of peripheral arteries in CT angiography of aortoiliac and lower extremity arteries.

Authors:  B C Meyer; A Oldenburg; B B Frericks; C Ribbe; W Hopfenmüller; K-J Wolf; T Albrecht
Journal:  Eur Radiol       Date:  2008-04-01       Impact factor: 5.315

2.  High-definition computed tomography for coronary artery stents: image quality and radiation doses for low voltage (100 kVp) and standard voltage (120 kVp) ECG-triggered scanning.

Authors:  Ji Won Lee; Chang Won Kim; Han Cheol Lee; Ming-Ting Wu; Lee Hwangbo; Ki Seok Choo; June Hong Kim; Ki-Nam Lee; Jin You Kim; Yeon Joo Jeong
Journal:  Int J Cardiovasc Imaging       Date:  2015-05-29       Impact factor: 2.357

3.  Do the cardiovascular risk profile and the degree of arterial wall calcification influence the performance of MDCT angiography of lower extremity arteries?

Authors:  B C Meyer; T Werncke; E Foert; M Kruschewski; W Hopfenmüller; C Ribbe; K-J Wolf; T Albrecht
Journal:  Eur Radiol       Date:  2009-09-30       Impact factor: 5.315

4.  Multi-detector row computed tomography angiography of peripheral arterial disease.

Authors:  Marc C J M Kock; Marcel L Dijkshoorn; Peter M T Pattynama; M G Myriam Hunink
Journal:  Eur Radiol       Date:  2007-09-20       Impact factor: 5.315

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.