Literature DB >> 16301144

An evaluation of the clinical application of three different biodegradable osteosynthesis materials for the fixation of zygomatic fractures.

Gert Wittwer1, Wasiu Lanre Adeyemo, Martin Voracek, Dritan Turhani, Rolf Ewers, Franz Watzinger, Georg Enislidis.   

Abstract

OBJECTIVE: The aim of this prospective study was to compare the clinical handling of 3 different biodegradable osteosynthesis materials and to determine whether they can be used for the fixation of all types of zygomatic fractures. STUDY
DESIGN: A total of 54 consecutive patients who presented with displaced fractures of the zygomatic bone between October 2001 and May 2003 were randomly allocated to 3 biodegradable material groups for the fixation of the fractures. A titanium fixation system was used as rescue osteosynthesis whenever biodegradable materials failed.
RESULTS: Seventy-one (75.5%) of 94 fracture sites were fixed with biodegradable osteosynthesis; 23 (24.5%) had to be fixed with titanium plates and screws. No statistically significant difference was found between the 3 biodegradable materials with regard to their suitability for zygomatic fracture fixation (P = .16). Nonstable fixation (n = 7) or the need to fix small fragments (n = 16) were the reasons for using the titanium fixation system as rescue osteosynthesis at these sites. Biodegradable materials were most frequently unfeasible for use at the infraorbital rim and in the zygomaticomaxillary/anterior sinus wall area.
CONCLUSIONS: It was possible to stabilize 3 of 4 zygomatic fractures with 1.5- or 1.7-mm biodegradable osteosynthesis. Insufficient fracture stabilization, especially at the infraorbital rim and the zygomaticomaxillary crest/anterior sinus wall, was the main reason to switch to titanium osteosynthesis. The biodegradable screw design is possibly too bulky for these particular bony structures.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16301144     DOI: 10.1016/j.tripleo.2005.03.024

Source DB:  PubMed          Journal:  Oral Surg Oral Med Oral Pathol Oral Radiol Endod        ISSN: 1079-2104


  2 in total

1.  Resorbable implants in maxillofacial surgery: a reality check.

Authors:  Suresh Menon; Col Sk Roy Choudhury
Journal:  J Maxillofac Oral Surg       Date:  2011-04-07

2.  Are Biodegradable Osteosyntheses Still an Option for Midface Trauma? Longitudinal Evaluation of Three Different PLA-Based Materials.

Authors:  Andreas Kolk; Robert Köhnke; Christoph H Saely; Oliver Ploder
Journal:  Biomed Res Int       Date:  2015-09-27       Impact factor: 3.411