Literature DB >> 16301074

Solving liquid chromatography mass spectrometry coelution problems in the analysis of environmental samples by multivariate curve resolution.

Emma Peré-Trepat1, Silvia Lacorte, Romà Tauler.   

Abstract

Multivariate curve resolution-alternating least squares (MCR-ALS) is shown to be a powerful tool to resolve coelution problems in liquid chromatograpy-mass spectrometry (LC-MS) in scan mode. This investigation was performed using two types of LC columns, one traditional LC column of 25 cm length with a slow gradient and a shorter LC column of 7.5 cm with a rapid gradient which allowed much faster analysis and save of reagents and solvents. Mixtures of multiple biocide compounds were simultaneously analyzed in standard mixtures and in environmental samples (sediment and wastewater samples) with little sample pretreatment. Using the more traditional LC 25 cm column, all biocide compounds were properly resolved by MCR-ALS and quantitatively analyzed with estimated errors always below 20%. When fast chromatography (LC column of 7.5 cm) was used, MCR-ALS resolution of the more strongly coeluted compounds was also achieved but limitations were found in their simultaneous quantitative determination, specially for environmental samples.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16301074     DOI: 10.1016/j.chroma.2005.04.089

Source DB:  PubMed          Journal:  J Chromatogr A        ISSN: 0021-9673            Impact factor:   4.759


  7 in total

1.  Mass spectrometric separation and quantitation of overlapping isotopologues. H2O/HOD/D2O and H2Se/HDSe/D2Se mixtures.

Authors:  Juris Meija; Zoltan Mester; Alessandro D'Ulivo
Journal:  J Am Soc Mass Spectrom       Date:  2006-05-19       Impact factor: 3.109

Review 2.  Lipidomics and Biomarker Discovery in Kidney Disease.

Authors:  Farsad Afshinnia; Thekkelnaycke M Rajendiran; Stefanie Wernisch; Tanu Soni; Adil Jadoon; Alla Karnovsky; George Michailidis; Subramaniam Pennathur
Journal:  Semin Nephrol       Date:  2018-03       Impact factor: 5.299

3.  Analysis of Vicinal Water in Soft Contact Lenses Using a Combination of Infrared Absorption Spectroscopy and Multivariate Curve Resolution.

Authors:  Shoichi Maeda; Shunta Chikami; Glenn Villena Latag; Subin Song; Norio Iwakiri; Tomohiro Hayashi
Journal:  Molecules       Date:  2022-03-25       Impact factor: 4.411

4.  Chemometric evaluation of Saccharomyces cerevisiae metabolic profiles using LC-MS.

Authors:  Mireia Farrés; Benjamí Piña; Romà Tauler
Journal:  Metabolomics       Date:  2014-06-25       Impact factor: 4.290

5.  Multivariate Curve Resolution for Signal Isolation from Fast-Scan Cyclic Voltammetric Data.

Authors:  Justin A Johnson; Josh H Gray; Nathan T Rodeberg; R Mark Wightman
Journal:  Anal Chem       Date:  2017-09-13       Impact factor: 6.986

6.  A new strategy for the computer-assisted development of reversed-phase liquid chromatography separation methods of unknown sample mixtures.

Authors:  R Cela; S Triñanes; C Cobas
Journal:  Anal Bioanal Chem       Date:  2021-08-18       Impact factor: 4.142

7.  Untargeted Metabolomics Analysis of Crocus cancellatus subsp. damascenus (Herb.) B. Mathew Stigmas and Their Anticarcinogenic Effect on Breast Cancer Cells.

Authors:  Raheleh Shakeri; Bahram Savari; Mahsa N Sheikholeslami; Tayebeh Radjabian; Jalal Khorshidi; Maliheh Safavi
Journal:  Evid Based Complement Alternat Med       Date:  2022-08-16       Impact factor: 2.650

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.