Closed-loop insulin delivery - what lies between where we are and where we are going?

Garry M Steil1, Kerstin Rebrin.   

Abstract

Closed-loop insulin delivery in individuals with diabetes can potentially lead to near-normal glucose profiles. To this end, existing subcutaneous glucose sensors and external insulin pumps can be linked with an insulin delivery algorithm to create a completely automated closed-loop system. This paper reviews current research into the development of such a system, with particular emphasis on creating a system emulating the physiological properties of the beta-cell. Issues related to using subcutaneous interstitial fluid for glucose sensing and insulin delivery are reviewed. Criteria for optimising the system are discussed using historical data. Existing strategies for open-loop pump therapy are presented with the objective of defining a path to advance from the existing physician/patient determined insulin therapy to a completely automated system.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16296759     DOI: 10.1517/17425247.2.2.353

Source DB:  PubMed          Journal:  Expert Opin Drug Deliv        ISSN: 1742-5247            Impact factor:   6.648


  12 in total

1.  Embryonic stem cell-based diabetes therapy--a long road to travel.

Authors:  P Serup
Journal:  Diabetologia       Date:  2006-09-23       Impact factor: 10.122

Review 2.  Stimuli sensitive polymers and self regulated drug delivery systems: a very partial review.

Authors:  Ronald A Siegel
Journal:  J Control Release       Date:  2014-06-28       Impact factor: 9.776

3.  Overnight closed-loop insulin delivery with model predictive control: assessment of hypoglycemia and hyperglycemia risk using simulation studies.

Authors:  Malgorzata E Wilinska; Erwin S Budiman; Marc B Taub; Daniela Elleri; Janet M Allen; Carlo L Acerini; David B Dunger; Roman Hovorka
Journal:  J Diabetes Sci Technol       Date:  2009-09-01

4.  A Pediatric Intensive Care Unit Bedside Computer Clinical Decision Support Protocol for Hyperglycemia Is Feasible, Safe and Offers Advantages.

Authors:  Eliotte L Hirshberg; Michael J Lanspa; Emily L Wilson; Katherine A Sward; Al Jephson; Gitte Y Larsen; Alan H Morris
Journal:  Diabetes Technol Ther       Date:  2017-03-01       Impact factor: 6.118

5.  The effect of insulin feedback on closed loop glucose control.

Authors:  Garry M Steil; Cesar C Palerm; Natalie Kurtz; Gayane Voskanyan; Anirban Roy; Sachiko Paz; Fouad R Kandeel
Journal:  J Clin Endocrinol Metab       Date:  2011-03-02       Impact factor: 5.958

Review 6.  Closed-loop insulin delivery: from bench to clinical practice.

Authors:  Roman Hovorka
Journal:  Nat Rev Endocrinol       Date:  2011-02-22       Impact factor: 43.330

7.  A model of glucose-insulin-pramlintide pharmacokinetics and pharmacodynamics in type I diabetes.

Authors:  Charrise M Ramkissoon; Brian Aufderheide; B Wayne Bequette; Cesar C Palerm
Journal:  J Diabetes Sci Technol       Date:  2014-02-09

Review 8.  Closed-loop insulin delivery in type 1 diabetes.

Authors:  Hood Thabit; Roman Hovorka
Journal:  Endocrinol Metab Clin North Am       Date:  2012-03       Impact factor: 4.741

9.  A Feedforward-Feedback Glucose Control Strategy for Type 1 Diabetes Mellitus.

Authors:  Gianni Marchetti; Massimiliano Barolo; Lois Jovanovič; Howard Zisser; Dale E Seborg
Journal:  J Process Control       Date:  2008-02       Impact factor: 3.666

10.  Overnight closed loop insulin delivery (artificial pancreas) in adults with type 1 diabetes: crossover randomised controlled studies.

Authors:  Roman Hovorka; Kavita Kumareswaran; Julie Harris; Janet M Allen; Daniela Elleri; Dongyuan Xing; Craig Kollman; Marianna Nodale; Helen R Murphy; David B Dunger; Stephanie A Amiel; Simon R Heller; Malgorzata E Wilinska; Mark L Evans
Journal:  BMJ       Date:  2011-04-13
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.