Literature DB >> 16294927

Formaldehyde exposure in some educational hospitals of Tehran.

Mehdi Ghasemkhani1, Farahnaz Jahanpeyma, Kamal Azam.   

Abstract

This research was conducted to determine formaldehyde exposure of staffs in pathology laboratories, surgery rooms and endoscopy wards in eight large hospitals of Tehran University of Medical Sciences located at Tehran, Iran. Air sampling have been made by both long and short-term methods. Total numbers of samples were 160 for both methods. Nineteen samples of 160 samples were collected as blank in other non-exposed environments such as administrative sections. The mean (SD) levels of formaldehyde in long-term methods were 0.96 (0.74), 0.25 (0.21) and 0.13 (0.18) ppm, at pathology laboratories, surgery rooms and endoscopy wards, respectively. The results of measurements showed that mean (SD) concentration of formaldehyde in one hour sampling at short intervals were 0.83 (0.29), 0.23 (0.16) and 0.75 (0.25) ppm at pathology labs, surgery rooms and endoscopy wards, respectively. There were significant differences in the mean levels of formaldehyde (long-term) at surgery rooms (p < 0.02) and endoscopy wards (p < 0.005) in eight hospitals of this study. It is concluded that the concentration levels of formaldehyde at pathology laboratories exceeded recommended limit which established by the American Conference of Governmental and Industrial Hygienists ACGIH (TLV-C = 0.3 ppm). It is recommended that local exhaust ventilation should be installed to minimize the contact to formaldehyde in the staffs.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16294927     DOI: 10.2486/indhealth.43.703

Source DB:  PubMed          Journal:  Ind Health        ISSN: 0019-8366            Impact factor:   2.179


  6 in total

1.  Preliminary study: Formaldehyde exposure in laboratories of Sharjah university in UAE.

Authors:  Hafiz Omer Ahmed
Journal:  Indian J Occup Environ Med       Date:  2011-01

2.  Chemical Characterization of the Indoor Air Quality of a University Hospital: Penetration of Outdoor Air Pollutants.

Authors:  Paul T J Scheepers; Luuk Van Wel; Gwendolyn Beckmann; Rob B M Anzion
Journal:  Int J Environ Res Public Health       Date:  2017-05-08       Impact factor: 3.390

3.  A strategy for the reduction of formaldehyde concentration in a hospital pathology laboratory.

Authors:  Masanori Ogawa; Isamu Kabe; Yasuhiro Terauchi; Shigeru Tanaka
Journal:  J Occup Health       Date:  2019-01       Impact factor: 2.708

4.  Occupational Exposure and Risk Assessment of Formaldehyde in the Pathology Departments of Hospitals.

Authors:  Elham Yahyaei; Behzad Majlesi; Mohammad Naimi Joubani; Yasaman Pourbakhshi; Samira Ghiyasi; Mehdi Jamshidi Rastani; Mahmoud Heidari
Journal:  Asian Pac J Cancer Prev       Date:  2020-05-01

Review 5.  Occupational scenarios and exposure assessment to formaldehyde: A systematic review.

Authors:  Vittoria Cammalleri; Roberta Noemi Pocino; Daniela Marotta; Carmela Protano; Federica Sinibaldi; Stefano Simonazzi; Marta Petyx; Sergio Iavicoli; Matteo Vitali
Journal:  Indoor Air       Date:  2021-10-27       Impact factor: 6.554

6.  VOC contamination in hospital, from stationary sampling of a large panel of compounds, in view of healthcare workers and patients exposure assessment.

Authors:  Vincent Bessonneau; Luc Mosqueron; Adèle Berrubé; Gaël Mukensturm; Sylvie Buffet-Bataillon; Jean-Pierre Gangneux; Olivier Thomas
Journal:  PLoS One       Date:  2013-02-05       Impact factor: 3.240

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.