Literature DB >> 16289612

Use of hand-held laser scanning in the assessment of craniometry.

Hee-Kyung Park1, Jin-Woo Chung, Hong-Seop Kho.   

Abstract

The intra- and inter-examiner reliability was evaluated for hand-held 3D laser scanning technology when it was combined with localization of landmarks for craniometry. The data from the laser surface scanning were compared with those of conventional direct measuring. Using thirty unidentified skulls requested for individual identification, measurements were taken of the line distances from lambda to 26 landmarks, and also for seven breadth parameters. For the laser surface scanning, two examiners performed replicate measurements with an interval of 1 week. In the conventional direct measuring, the first examiner took replicate measurements with a 1-week interval. To assess intra- and inter-examiner reliabilities, the intraclass correlation coefficient was used. Analysis of variance with repeated measures for each parameter was performed to compare the conventional method with the 3D scanning method. Both the 3D scanning and conventional methods showed excellent intra-examiner reliabilities, and the 3D laser scanning method also showed excellent inter-examiner reliability. A statistical difference between the two examiners was found only in nasal breadth in the 3D laser scanning method. There was no significant difference between the two measuring methods, though the 3D laser scanning method tended to give a slightly lower reading. Collectively, the 3D laser scanning method with point localization is a useful method with excellent reliability, and it can replace the conventional direct measuring method in craniometry.

Mesh:

Year:  2005        PMID: 16289612     DOI: 10.1016/j.forsciint.2005.10.007

Source DB:  PubMed          Journal:  Forensic Sci Int        ISSN: 0379-0738            Impact factor:   2.395


  3 in total

1.  State-of-The-Art and Applications of 3D Imaging Sensors in Industry, Cultural Heritage, Medicine, and Criminal Investigation.

Authors:  Giovanna Sansoni; Marco Trebeschi; Franco Docchio
Journal:  Sensors (Basel)       Date:  2009-01-20       Impact factor: 3.576

2.  Analysis of the upper massif of the craniofacial with the radial method - practical use.

Authors:  Tomasz Lepich; Józefa Dąbek; Daniel Stompel; Jerzy S Gielecki
Journal:  Arch Med Sci       Date:  2011-11-08       Impact factor: 3.318

3.  Computed Tomography versus Optical Scanning: A Comparison of Different Methods of 3D Data Acquisition for Tooth Replication.

Authors:  Tomasz Kulczyk; Michał Rychlik; Dorota Lorkiewicz-Muszyńska; Monica Abreu-Głowacka; Agata Czajka-Jakubowska; Agnieszka Przystańska
Journal:  Biomed Res Int       Date:  2019-04-10       Impact factor: 3.411

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.