Ocular delivery using poly(ortho esters).

Jorge Heller1.   

Abstract

Three families of poly(ortho esters) were investigated as a means of delivering 5-fluorouracil (5-FU), an antiproliferative agent used as an adjunct to glaucoma filtering surgery. Release of 5-FU from a crosslinked POE II occurred predominantly by diffusion with little weight loss, while release of 5-FU from a linear polymer occurred by an erosion-controlled process confined predominantly to the surface layers. No ocular biocompatibility studies were carried out. Rate of release of 5-FU from POE III, a viscous, injectable material, could be controlled by polymer molecular weight and polymer hydrophobicity. Excellent biocompatibility was demonstrated in subconjunctival, intravitreal and suprachoroidal injections. Polymer lifetime in the various sites investigated was between 1 and 3 weeks. The effect of sustained 5-FU release was investigated in rabbits that underwent a trabeculectomy and the effectiveness of maintaining low intraocular pressure for 1 month demonstrated. Release of 5-FU from POE IV was investigated using both solid and viscous, injectable materials. Good control over rate of 5-FU release by an erosion-controlled process was achieved from both types of formulations. Excellent biocompatibility was demonstrated in subconjunctival, intracameral, intravitreal and suprachoroidal injections. Lifetimes in the various sites ranged from 5 weeks for subconjunctival injections to 3 months for intravitreal injections to more than 6 months for intracameral and suprachoroidal injections.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16289431     DOI: 10.1016/j.addr.2005.09.007

Source DB:  PubMed          Journal:  Adv Drug Deliv Rev        ISSN: 0169-409X            Impact factor:   15.470


  3 in total

Review 1.  New techniques for drug delivery to the posterior eye segment.

Authors:  Esther Eljarrat-Binstock; Jacob Pe'er; Abraham J Domb
Journal:  Pharm Res       Date:  2010-02-13       Impact factor: 4.200

Review 2.  Critical assessment of implantable drug delivery devices in glaucoma management.

Authors:  Dharani Manickavasagam; Moses O Oyewumi
Journal:  J Drug Deliv       Date:  2013-08-26

Review 3.  Bioresponsive drug delivery systems for the treatment of inflammatory diseases.

Authors:  Yin Dou; Chenwen Li; Lanlan Li; Jiawei Guo; Jianxiang Zhang
Journal:  J Control Release       Date:  2020-09-08       Impact factor: 9.776