Literature DB >> 16287121

Mechanical contribution of the fibula to torsion stiffness in the lower extremity.

A Thambyah1, B P Pereira.   

Abstract

The role of the fibula in rotational stability of the lower extremity, taking into account the intact knee joint and tibia, to the best of our knowledge, has not been investigated. A cadaver study was designed to determine the torque transfer down the lower extremity, with and without the fibula. Six fresh, frozen human cadaver legs were used. The knee joint was left intact and the foot disarticulated. An external rotation up to 5 degrees , coupled with axial compression, was applied to the femur passing through the knee joint in extension and down the lower extremity to the fixed distal end, where torque (N m) was measured via a load cell. Each specimen was further tested with the fibula, cut 4 cm from the distal end, and finally with the entire fibula disarticulated at the proximal end and removed. To achieve 5 degrees rotation, torques reached 1.82 N m (SD, 0.66 N m). When the fibula was cut, the torque reduced a small yet significant amount of 5%. With the entire fibula removed, the torque reduction was significant and more pronounced at 11%. The fibula provided a small yet significant role in torsion stability. From this study, where the biomechanical characteristics of the fibula is explicated, it is hoped that this information will have use in further understanding the biomechanical role of the fibula, especially, in relation to the altered mechanics associated with lower limb pathology involving a deficient fibula. Copyright 2006 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2006        PMID: 16287121     DOI: 10.1002/ca.20234

Source DB:  PubMed          Journal:  Clin Anat        ISSN: 0897-3806            Impact factor:   2.414


  3 in total

1.  Meagre effects of disuse on the human fibula are not explained by bone size or geometry.

Authors:  A Ireland; R F Capozza; G R Cointry; L Nocciolino; J L Ferretti; J Rittweger
Journal:  Osteoporos Int       Date:  2016-10-12       Impact factor: 4.507

2.  Plating of pilon fractures based on the orientation of the fibular shaft component: A biomechanical study evaluating plate stiffness in a cadaveric fracture model.

Authors:  Gennadiy A Busel; J Tracy Watson
Journal:  J Orthop       Date:  2017-04-17

3.  A Biomechanical Comparison Of Pin Configurations Used For Percutaneous Pinning Of Distal Tibia Fractures In Children.

Authors:  Justin Brantley; Aditi Majumdar; J Taylor Jobe; Antony Kallur; Christina Salas
Journal:  Iowa Orthop J       Date:  2016
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.